Troubleshooting - Troy-Bilt 01925 Manual Del Propietário

Ocultar thumbs Ver también para 01925:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING

Problem
No AC output is available, but
generator is running.
Generator runs good at no-load
but "bogs" down" when loads are
connected.
Generator will not start; or starts
and runs rough.
Generator shuts down during
operation.
Generator lacks power.
Cause
1.
One of the circuit breakers is
open.
2.
Fault in generator.
3.
Poor connection or defective
cord set.
4.
Connected device is bad.
1.
Short circuit in a connected load.
2.
Generator is overloaded.
3.
Shorted generator circuit.
1.
10 Amp in-line fuse is blown.
2.
Discharged battery.
3.
Failed battery.
4.
Low oil level.
1.
Out of gasoline.
2.
Low oil level.
Load is too high.
17
Troubleshooting
Correction
1.
Reset circuit breaker.
2.
Contact Authorized service
facility.
3.
Check and repair.
4.
Connect another device that is in
good condition.
1.
Disconnect shorted electrical
load.
2.
See "Don't Overload Generator".
3.
Contact Authorized service
facility.
1.
Replace fuse.
2.
Jump start generator and/or
charge battery.
3.
Replace battery.
4.
Fill crankcase to proper level or
place generator on level surface.
1.
Fill fuel tank.
2.
Fill crankcase to proper level or
place generator on level surface.
See "Don't Overload Generator".
Section
7

Publicidad

Capítulos

Tabla de contenido
loading