SECTION 6 − OPERATING THE WELDING GENERATOR
6-1. Controls
1
1
Engine Switch
Use switch to control ignition circuit, and to
stop engine.
2
Choke Control
Use control to change engine air/fuel mix.
Move control to left (Choke) if starting a cold
engine. Move control to right (Run) if starting
a warm engine.
3
Starter Handle
To Start:
D Open fuel valve (see Section 5-3).
D Place engine switch in RUN position.
D Set Choke control.
OM-267 225 Page 20
.
Complete Parts List available at www.HobartWelders.com
2
D Pull starter handle until engine starts.
D Move Choke control to the right (Run) as
the engine warms.
.
This unit has a low oil level shutdown to
prevent starting an engine that is too low
on oil. The low oil level shutdown may not
stop a running engine. Check oil level if
the engine does not start, or has stopped
and cannot be restarted.
To Stop: Place engine switch in OFF position.
.
Always close fuel valve after stopping
unit. Moving unit with fuel valve open may
cause carburetor flooding and make
starting difficult.
3
4
Amperage Control
Use control to select weld amperage. Control
may be adjusted while welding. Set Amper-
age control at MAX for full generator power
output at AC receptacles.
To Set Amperage control: Use electrode
chart (see Section 6-2) to determine correct
size electrode. Select electrode type and set
Amperage control to corresponding amper-
age range on nameplate. Adjust control within
selected range to obtain desired weld
performance.
EXAMPLE:
Electrode Type: 6013
Electrode Diameter: 1/8
Amperage control Setting: 80 − 120 A
4
268 244 / 268 258 / 265 288-A