Replacing The Flow Rate Regulator; Replacing The Non-Return Valve; Fault Correction - Franke FAID100 Instrucciones De Montaje Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Ensure correct installation position.
16.7 Replace the filter (c).
Important!
The filter contains the connection seal.
16.8 Reassemble in the reverse order.

17. Replacing the Flow Rate Regulator

17.1 Close the isolating valve.
17.2 Take the eye-wash fountain (a) from the wall mounting (b).
17.3 Loosen the union nut (c).
17.4 Lift out the flow rate controller with a bent wire and replace it.
Ensure correct installation position.
Do not forget the seal.
17.5 Reassemble in the reverse order.

18. Replacing the Non-return Valve

The non-return valve must be replaced every 2 years.
18.1 Loosen the screws (a).
18.2 Remove the jet plate (b).
18.3 Remove the spray heads (c) and seals (d).
18.4 Unscrew the attachment part (e).
18.5 Remove the washer (f).
18.6 Push out the non-return valve (g).
18.7 Reassemble in the reverse order.

19. Fault Correction

Fault
Water flow too weak
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Cause
– Flow rate controller faulty
– Grit filter is clogged
Remedy
➯ Replace it
➯ Clean it
9

Publicidad

Tabla de contenido
loading

Tabla de contenido