16. Replacing the Grit Filters

Filter for corner valve
16.1 Close the corner valve (c).
16.2 Trigger the valve.
16.3 Unscrew the connecting hose (a) together with the connector piece from the corner
valve.
16.4 Replace the filter (b).
16.5 Reassemble in the reverse order.
Filter for solenoid valve
16.6 Remove the solenoid valve cartridge (see
16.7 Use a flat nose pliers to pull the filter (d) out.
16.8 Replace the filter.
Important!
Ensure correct installation position. The rib of the filter must not lie on the flow-
through hole.
Reassemble in the reverse order.

17. Replacing the Flow Rate Regulator

17.1 Close the corner valve (c).
17.2 Trigger the valve.
17.3 Unscrew the connector hose (a) from the connector piece (b).
17.4 Unscrew the connector piece (b) from the corner valve (b).
17.5 Press the flow rate controller (d) out of the connector piece and replace it.
17.6 Reassemble in the reverse order.

18. Replacing the Solenoid Valve Cartridge

18.1 Close the corner valves.
18.2 Trigger the valve.
18.3 Loosen the screw (a) with a hollow hexagon wrench.
18.4 Pull the housing (b) from the base (c).
18.5 Remove the screws (d).
18.6 Remove the mounting bracket (e).
18.7 Remove and replace the solenoid valve cartridge (f).
18.8 Reassemble in the reverse order.