Maintenance And Servicing; Replacing The Flow Rate Regulator; Fault Correction - Franke AQRM962 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

12. Maintenance and Servicing

Depending on the quality of the water, the local conditions and the rules and regula-
tions applicable on site, the shower head must be maintained and serviced at
regular intervals.
Use suitable cleaning agents that are not harmful to the shower head in a proper
manner and rinse with water after use. High-pressure cleaners must not be used for
cleaning.

13. Replacing the Flow Rate Regulator

13.1 Loosen the grub screw using a hollow hexagon wrench.
13.2 Pull the shower head from the connection spigot.
13.3 Use a face spanner to loosen and remove the retaining ring.
13.4 Remove the following parts from the shower head.
a: Seal
b: Ball
13.5 Replace the flow rate regulator. Note details provided in the table.
13.6 Insert the following parts into the shower head.
a: Seal
b: Ball
13.7 Use a face spanner to tighten the retaining ring (a).
13.8 Slide the shower head onto the connection spigot.
13.9 Screw-in the grub screw using a hollow hexagon wrench.

14. Fault Correction

Fault
Spray pattern is
irregular
Water flow too weak
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
6
Cause
– Shower head is dirty
– Flow rate controller faulty
– Shower head is dirty
– Flow rate controller faulty
Remedy
➯ Clean it
➯ Replace it
➯ Clean it
➯ Replace it

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Aqrm963

Tabla de contenido