• DMX512 Start Address
All DMX-controlled devices need a digital start address so that the correct device responds to the
signals. This start address is the channel number from which the device starts to "listen" to the DMX
controller. Enter the correct number and read it from the display located on the base of the
VDPL300MF6.
You can use the same starting address for a whole group of devices or enter an individual one for
every device.
When all devices have the same address, all the VDPL300MF6s will "listen" to the control signal on
one particular channel. In other words: changing the settings of one channel will affect all devices
simultaneously. If you set different addresses, each device will "listen" to a separate channel
number. Changing the settings of one channel will only affect the device in question.
In the case of the 10-channel VDPL300MF6, you will have to set the start address of the first
VDPL300MF6 to 1, the second VDPL300MF6 to 11 (1 + 10), the third to 21 (11 + 10) and so on.
8.
Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling,
suspension, trussing) should not be deformed, modified or tampered with e.g. do not drill extra
holes in mounting supports, do not change the location of the connections.
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician
maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts.
8. Contact your dealer for spare parts if necessary.
9.
Technical Specifications
Power Supply
Power Consumption
DMX Channels
DMX Connections
LEDs
Dimensions
Total Weight
Use this device with original accessories only. Velleman Components nv cannot be held
responsible in the event of damage or injury resulted from (incorrect) use of this device.
For more info concerning this product, please visit our website www.hqpower.com. The
information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
This manual is copyrighted. The copyright to this manual is owned by Velleman Components
nv. All worldwide rights reserved. No part of this manual may be copied, reproduced, translated or
reduced to any electronic medium or otherwise without the prior written consent of the copyright
holder.
VDPL300MF6
230VAC/50Hz
50W
10
3-pin XLR
469 x 5mm
800 x 700 x 800mm
5kg
6
HQPOWER™