Error code
Description
C - 1
Basic parameter error in flash or RAM - Meter must be replaced
E 1
Temperature range outside [-19.9 °C...199.9 °C] e.g. sensor short-circuit,
sensor break
E 3**
Forward and return sensor reversed
E 4
Hardware error US measurement, e.g. transducer or control defective or short
circuit
E 5
Communication not possible (too frequent read-out)
E - 6**
Flow direction of flow meter incorrect
E 7
No plausible ultrasound receiver signal, e.g. air in the measuring path
E 8
No primary power supply (only with power supply unit); supply via backup
battery
E 9
Battery nearly discharged, design lifetime reached
E A*
Leak: Pipe break detection
E b*
Leak: Energy meter leak detection
E C*
Leak: Leak pulse input 1
E d*
Leak: Leak pulse input 2
* optional ** application dependent
11.
Disposal
This product must be disposed of separately. Contact a designated collec-
tion point for old batteries or your Diehl Metering specialist dealer.
12.

Declaration of Conformity for devices according to MID

See from page 80 onwards.
Further information as well as the actual declaration of conformity are
available at: http://www.diehl.com/en/diehl-metering/products-solutions/
product-download/
Please select the partner "Diehl Metering GmbH" and the product area
"Thermal Energy Metering".
-39-

Publicidad

Tabla de contenido
loading

Tabla de contenido