Display Error codes
If an error occurs, the error code is displayed in the main loop. All win-
dows, however, can still be accessed by pressing the button. If the button
is not pressed for approx. 4 min, the error code is automatically displayed
again.
The error message disappears automatically as soon as the source of the
error is corrected. All errors that exist for longer than 6 min, are saved in
the error memory.
Error code
Description
C - 1
Basic parameter error in flash or RAM - Meter must be replaced
E 1
Temperature range outside [-19.9 °C...199.9 °C] e.g. sensor short-circuit,
sensor break
E 3*
Forward and return sensor reversed
E 4
Hardware error US measurement, e.g. transducer or control defective or short
circuit
E 5
Communication not possible (too frequent read-out)
E 6*
Flow direction of flow meter incorrect
E 7
No plausible ultrasound receiver signal, e.g. air in the measuring path
E 9
Battery nearly discharged, design lifetime reached
* application dependent