Operating Modes
Normal Operation (Utility Power) Mode
When connected to a live power source, the MB1000 provides
power and is ready to provide protection from under- and over-
voltages.
Normal Operation Screen
SETUP
Rotate the navigation dial to scroll through the screens.
Automatic Voltage Regulation (AVR) Mode
Sensitive AVR: when receiving input voltages of 99 VAC – 135
VAC, the MB1000 supplies a regulated voltage of 120 VAC ± 5
VAC.
Standard AVR: when receiving input voltages of 94 VAC – 142
VAC, the MB1000 supplies a regulated voltage of 120 VAC ± 10
VAC.
OFF: AVR is disabled. No voltage correction.
UPS Mode
In the event of a loss of power to the unit, over-voltage, or
under-voltage, the MB1000 will function as a battery back-up. An
audible alarm will sound and the display will indicate the fault as
well as the number of minutes of battery life remaining.
Setup Mode
The setup menu allows the user to adjust several of the operating
parameters of the unit.
Please refer to diagram (page 5) for a detailed map of the menu
structure.
120 VOLTS
NORMAL POWER
UPS Mode Screen
FAULT
BATTERY: 15 MIN
Setup Menu Navigation
Clockwise (CW) rotation of the navigation dial advances the
menu to the next item. If the menu is at the last item, SYSTEM
INFO, return to Normal Operation Mode.
Counter clockwise (CCW) rotation of the navigation dial sends
the menu to the previous item. If the menu is at the first item,
DISPLAY BRIGHTNESS, return to Normal Operation Mode.
Pressing the navigation dial selects the current menu item.
If there is no activity of the navigation dial for 60 seconds, the
menu will automatically return to Normal Operation Mode.
Parameter Selection and Adjustment
CW rotation of the navigation dial INCREASES the selected
parameter, or advances to the NEXT available value.
CCW rotation of the navigation dial DECREASES the selected
parameter, or goes back to the PREVIOUS value. Pressing the
navigation dial selects the current parameter value.
If there is no activity of the navigation dial for 60 seconds, return
to Normal Operation Mode.
If the BACK parameter is selected, return to the menu item selec-
tion.
Display Brightness
Display Brightness adjusts the brightness of the display back-
light.
Display Scroll Mode
If enabled, the display will automatically advance to the next
screen every 5 or 10 seconds.
Display Sleep Mode
With Display Sleep Mode enabled, the Display will go to the
lowest brightness setting (25%) after the designated time of
inactivity of the Navigation Dial {30 SEC, 60 SEC }.
The display will return to the set brightness level upon entering
Setup Mode, or UPS Mode.
4