HQ-Power VDP150MH6N Manual Del Usuario página 4

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

• Familiarise yourself with the functions of the device before actually using it. Do not allow operation by unqualified
people. Any damage that may occur will most probably be due to unprofessional use of the device.
• Use the original packaging if the device is to be transported.
• All modifications of the device are forbidden for safety reasons.
• Only use the device for its intended purpose. All other uses may lead to short circuits, burns, electroshocks,
crash, etc. Using the device in an unauthorised way will void the warranty.
4. Installation
a) Lamp
• Only fit or replace the lamp when the device is unplugged from the mains. Replace any deformed or damaged
lamp.
• Let the lamp cool for 10 minutes before replacing it as its temperature can reach 700°C during operation.
• Do not touch the lamp with your bare hands when you're installing a halogen lamp. Use a cloth to insert or
remove a halogen lamp.
• Do not install lamps with a higher wattage. The temperatures they generate are too hot for this device.
• Insert one 230V/150W HTI GY9.5 lamp (order code LAMP150HTI):
1) Unscrew the screws of the lamp cover. Remove the cover.
2) Unscrew the knurled screws of the lamp holder and remove it.
3) Remove the old lamp from the lamp holder. Insert the lamp into the lamp holder and replace it into the device.
Tighten the knurled screws.
4) Adjust the lamp as described in "Lamp Adjustment".
5) Replace the lamp cover and tighten the fixation screws.
Remark: Do not operate the device when the cover is off.
b) Lamp Adjustment
The lamp holder is aligned at the factory. Due to difference between lamps, fine adjustment may improve light
performance. Strike the lamp, open the shutter and the iris, set the dimmer to 100% and focus the light on a flat
surface (wall). Centre the hot spot (brightest part of the beam) using the 3 adjustment screws (A, B and C). Turn one
screw at the time to drag the hot spot diagonally across the projected image. If you cannot detect the hot spot, adjust
the lamp until the light is evenly distributed.
To reduce the hot spot, push the lamp in by turning all three screws (A, B and C) clockwise ¼ turn a time until the
light is evenly distributed. If the light is brighter around the edge than in the centre, the lamp is too far back in the
reflector. Pull the lamp out by turning the screws (A, B and C) anticlockwise ¼ turn at a time until the light is evenly
distributed.
c) Inserting / Exchanging the Gobos
Remove the fixation ring with an appropriate tool. Remove the gobo and insert a new one. Press the fixation ring
together and insert it in front of the gobo.
Remark: Never unscrew the screws of the rotating gobo as the ball bearing will be opened.
d) Fuse
• If the lamp burns out, the fuse of the device might fuse, too.
• Only replace the fuse by a fuse of the same type and rating.
• Before replacing the fuse, unplug mains lead.
1) Unscrew the fuse holder on the rear panel of the base with a fitting screwdriver.
2) Remove the old fuse and install the new fuse in the fuse holder.
3) Replace the fuse holder in the housing and fix it.
VDP150MH6N