FEATURES
The Family Ultrasound Aerosol is ideal for the treatment of asthma, of respiratory problems
and other pathologies of the breathing organs, which require aerosol drug therapy. It operates
with running or distilled water and the aerosol drug prescribed by the doctor. The product
cannot be used with Pentamidine or other substances that are not suitable for inhalation.
Technical Features
Power supply: 230V AC 50Hz - 10W
Ultrasound frequency: 2,5 MHz
Nebulization: from 0.2 to 0.7 ml/minute according to the density of the medicine
Capacity of the medicine holder cup: maximum 8 ml
Timer: approx. 10 minutes
Dimensions (without battery): 8,2 cm x 5 cm x 13,2 cm
Weight (without battery): approx. 250 gr.
Accessories: Power adapter R , case, mouth piece A , 5 re-usable medicine holder cups
E, Masks S , extensible tube T, travel power adapter and rechargeable battery Q
Type of battery: Ni-MH 12V DC - 600mAH
CAUTION
- The supervision of an adult is necessary when the unit is used with children; do not
leave the unit, even when it is switched off, or any of its components, near the reach
of children.
- Do not expose eyes to the steam coming out of the unit
- Follow the aerosol therapies only upon doctor's suggestion. Do not nebulize incorrect
substances or substances that are not authorized by your doctor!
- DO NOT use the unit near water sources (sink, bath tub, etc.) or near other electric appliances.
- Do not use the unit if it is damaged. Contact your dealer and avoid any temporary repair.
- Do not block the air inlet from the ring B with towels or other objects.
- Do not open the lid D during use.
- Disconnect the device from the mains before cleaning it, filling it and in any case at the end
of each use.
- Empty out the water from the tank I after each use. Only water can be used inside the tank.
Other substances may damage the product!
OPERATION
Caution: Do not switch on the device if the tank I or medicine holder cup E are
empty. Always fill the tank I with water up to the level H between the two marks.
ALWAYS use the medicine holder cup E. The water in the tank I is used to transfer
the ultrasounds and cool off the device and NOT to dilute the drug!
Remove the lid D by pulling it upwards. Remove the medicine holder cup E and pour running
water or distilled water (preferable) at room temperature (20/30°C)inside the tank I. Fill the tank
I up to the level H indicated between the two marks.
Fix the medicine holder cup E above the tank and pour over the medicine. The maximum capacity
of the cup is 8 ml, the ideal quantity is 4 ml. If necessary (for dense drugs with less than 2 ml of
volume) dilute the drug with distilled water or saline solution (follow the doctor's instructions).
Close the lid D until it clicks.
Connect the power adapter R to the power outlet and the plug to the outlet under the unit. When
using the rechargeable battery Q assemble as described below.
ENGLISH
6