TROUBLESHOOTING
SYMPTOM
Excessive use of turbo
mode
Battery pack not fully
Low use time per
charged
battery charge
Battery pack is at the
end of its life
Charger short circuit,
charger over current,
Blinking orange
over voltage limit, open
light on charge
circuit on battery pack
state indicator
or charge/pre-charge
time out error
22
POSSIBLE CAUSE
Use turbo only when needed to move dense,
heavy or wet material.
Recharge. See "Battery Pack and Charger".
All batteries have a finite life. If the battery pack
is more than two years old or has been recharged
frequently, it may be time to replace it. Replace
only with the battery pack specified for this blower.
1. Make sure the charger cord is connected to both
2. Make sure the charger is receiving the correct
3. Try charging another battery pack designed for
If this does not correct the problem, have the
function checked at an approved service location.
OREGON® Cordless Tool System
BLOWER MODEL BL300
RECOMMENDED ACTIONS
the charger and the electrical outlet.
voltage.
this charger.
AA 1214 - F/N 571702