PUMPTEC-PLUS Pump Protection System
Operation cont.
A. GREEN LIGHT
B. YELLOW LIGHT
C. RED LIGHT
D. RESET BUTTON
A. Green Light
The green light (A) indicates that the status of the pump system is normal.
A SOLID GREEN LIGHT indicates that Pumptec-Plus has power and the contactor to the
motor is closed but the motor is not running. This may happen when the pressure switch is
wired in down-line from Pumptec-Plus and the switch is open. Pumptec-Plus is waiting for
the pressure switch to close.
A FLASHING GREEN LIGHT indicates the pump motor is running normally and drawing the
correct amount of power.
B. Yellow Light
The yellow light (B) indicates that a load fault has occurred.
A SOLID YELLOW LIGHT indicates an underload fault occurred. The Pumptec-Plus
automatic restart timer will restart the motor in accordance with the position of the
automatic restart timer switch setting. The switch should be set at the time of installation
(refer to step 2). If set in the manual position, Pumptec-Plus must be reset manually by
pushing the RESET BUTTON (D).
A FLASHING YELLOW LIGHT indicates an overload condition occurred. This means that
the pump system power draw was greater than the normal operating power (calibration)
by more than 25% for more than 2.5 seconds. Pumptec-Plus will not run the pump system
again until the RESET BUTTON (D) is pressed.