ENGLISH
3.4
Auxiliary Load Operation (for VS-
FHP2.0)
The VS-FHP2.0 is equipped with a terminal bar that
provides user access to a built-in Auxiliary Load relay
contact. This normally-open, dry contact is activated
under certain operating conditions and is primarily
intended to be used to control external devices that
require system water flow for proper functioning, such as
heaters, booster pumps, salt water chlorinators, etc.
See Figures 9 and 10 for compartment's location details.
An access cover with Phillips-head screw must be
removed before proceeding.
Auxiliary Load Connection Requirements
WARNING
ELECTRICAL SHOCK HAZARd
Due to the potential risk of fire, electric shock,
or injuries to persons, Zodiac® Pumps must be
installed in accordance with the National Electrical
Code
(NEC
), all local electrical and safety codes,
®
®
and the occupational Safety and Health Act (OSHA).
Copies of the NEC may be ordered from the National
Protection Association, 470 Atlantic Ave., Boston,
MA 02210, or from your local government inspection
agency.
In Canada, Zodiac Pumps must be installed in
accordance with the Canadian Electrical Code
(CEC).
Note: The Auxiliary Load relay contacts are rated at
230V/11A RMS. Please ensure the requirements of the
equipment to be connected to the Auxiliary Load do not
exceed this rating.
1
2
F1015
TP133
TP130
/100
TP127
Earth
230V
Earth
Auxiliary
Load
Note: In this configuration, it is important to verify the shared
power source is adequately rated to service both the pump
and the auxiliary equipment.
Figure 12. 230V Auxiliary Load, Shared Power
Source Wiring diagram
Jandy
Pro Series VS FloPro™ Series Variable-Speed Pump
®
L2 L1
F1014
L1
(Black)
230V
Power
Source
L2
(Red or
Black)
L2
(Red or Black)
1
2
TP133
TP130
/100
TP127
Line
(Black)
115V
Power
Source
Neutral
(White)
(Black)
115V
Earth
Auxiliary
Load
Figure 13. 115V Auxiliary Load, Separate Power
Sources Wiring diagram
1
2
TP133
TP130
/100
TP127
L1
(Black)
230V
Power
Source
L2
(Red or Black)
Line
(Black)
230V
Earth
Auxiliary
Load
Figure 14. 230V Auxiliary Load, Separate Power
Sources Wiring diagram
Auxiliary Load Operation Characteristics
Auxiliary Load relay contact activation is speed-
dependent, and behaves as follows:
Contact Closure
From a stopped condition, there is a three-minute delay
before the Auxiliary Load contact is closed when the
motor speed reaches and maintains a speed of at least
1725 RPM.
From a running condition at below 1725 RPM, there is
a five-second delay before the Auxiliary Load contact
is closed when the motor speed reaches and maintains a
speed of at least 1725 RPM.
|
Installation & Operation Manual
L2 L1
L1
F1015
F1014
(Black)
L2
(Red or
Black)
Earth
Line
L2 L1
F1015
F1014
L1
(Black)
Source
L2
(Red or
Black)
Earth
230V
Power
Source
230V
Power