Pro Series VS FloPro™ Series Variable-Speed Pump
®
Figure 2.
Typical Piping Installation
NOTE
In Canada, the minimum distance maintained from
the edge of the pool and/or spa as noted above must be
3 meters (10 feet), as required by the Canadian Electrical
Code (CEC, CSA C22.1).
4.
The pump must be placed on a solid foundation that
will not vibrate. To further reduce the possibility of
vibration noise, bolt the pump to the foundation, or
place it on a rubber mat.
NOTE
Zodiac Pool Systems, Inc. recommends bolting the
pump directly to the foundation.
5.
The pump foundation must have adequate drainage
to prevent the motor from getting wet. Protect the
pump from the rain and sun.
6.
Proper ventilation is required for the pump to
operate normally. All motors generate heat that
must be removed by providing proper ventilation.
7.
Provide access for future services by leaving a clear
area around the pump. Allow plenty of space above
the pump to remove the lid and basket for cleaning.
8.
If the equipment is in a potentially dark area,
provide adequate lighting.
Pipe Sizing
Suction Pipe
When the pump is located up to 50 feet (15 m) from the
pool, the recommended minimum pipe size for the suction
side of the pump is two (2) inches (5 cm). For suction
lengths greater than 50 feet. See Table 1.

discharge Pipe

When the pump is located up to 50 feet (15 m) from
the pool, the recommended minimum pipe size for the
discharge side of the pump is two (2) inches (5 cm). For
discharge lengths greater than 50 feet. See Table 1.
|
Installation & Operation Manual
AQUAPURE

Installation Recommendations

1.
To help prevent difficulty in priming, install the
suction pipe without high points (above inlet
of pump - inverted "U"s, commonly referred to
in plumbing as an airlock) that can trap air. For
installations of equipment up to 100 feet (30 m)
from the water, refer to Table 1, the pipe sizing
chart. For installations of equipment more than 100
feet (30 m) from the water, the recommended pipe
size must be increased to the next size.
Table 1.
Pipe Sizing Chart for Schedule 40 PVC
Pipe Size
1½"
(38 mm)
2"
(51 mm)
2½"
(64 mm)
3"
(76 mm)
4"
(102 mm)
2.
VS FloPro Pumps come equipped with unions on
both the suction and discharge ports. This feature
simplifies installation and service and eliminates
the possibility of leaks at threaded adapters.
3.
The VS FloPro Pump must be connected to at least
two (2) hydraulically-balanced main drains for each
pool pump suction line. Each drain (suction outlet)
assembly must be provided with covers and must be
listed or certified to the latest published edition of
ANSI
/ASME
®
ANSI
/APSP-16. The suction fittings of the main
®
drains must be at least three (3) feet (1 m) apart or at
different planes. The suction fittings can be a drain
and skimmer, two (2) drains, two (2) skimmers, or a
ENGLISH
MANUAL BY-PASS DETAIL
MANUAL BY-PASS IS USED
WHEN FILTRATION RATE
EXCEEDS 125 GPM FOR
ZODIAC HEATERS. REFER
TO THE MANUFACTURER'S
RECOMMENDATIONS IF
USING A DIFFERENT
BRAND HEATER.
Maximum Flow
Maximum Flow
Suction
(6 feet per second)
(8 feet per second)
37 GPM (140 LPM)
50 GPM (189 LPM)
62 GPM (235 LPM)
85 GPM (322 LPM)
88 GPM (333 LPM)
136 GPM (515
LPM)
234 GPM (886
313 GPM (1185
LPM)
A112.19.8, or its successor standard,
®
Page 7
discharge
120 GPM (454
LPM)
184 GPM (697
LPM)
LPM)