Zodiac Jandy VS FloPro Serie Manual Del Usuario página 19

Ocultar thumbs Ver también para Jandy VS FloPro Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Jandy
Pro Series VS FloPro™ Series Variable-Speed Pump
®
Symptom
Pump will not start.
Variable-Speed Controller
LCD is not displaying
information
or
pump LEDs are not
illuminated.
Controller displays "Pump
not connected".
Fault message appears on
controller display.
|
Installation & Operation Manual
No power to pump.
Make sure pump is properly connected to high voltage. See Section 3.2, Electrical
Installation, in this manual.
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See
Section 3.2, Electrical Installation, in this manual.
Improper pump address setting.
Make sure that pump dip switches 3 and 4 are set properly for the installation. Both
should be OFF for use with Variable-Speed Controller or set to the proper address
when connected to an AquaLink
Z4. See Section 3.3, VS-FHP Pump Dip Switch Settings, in this manual. Note: VS-
FHP1.0 should always have dip switch setting 5 set to ON for both controllers.
Fault condition exists.
View fault message on controller and correct fault before proceeding. If unsure how
to correct fault, contact Zodiac
1-888-647-4004
Incorrect dip switch setting.
Make sure pump dip switches 1 and 2 are both ON if the controller is the JEP-R and
both are OFF if the controller is a PDA, AquaLink RS, or AquaLink Z4. See Section
3.3, VS-FHP Pump Dip Switch Settings, in this manual. Note: VS-FHP1.0 should
always have dip switch setting 5 set to ON for both controllers.
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See
Section 3.2, Electrical Installation, in this manual.
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See
Section 3.2, Electrical Installation, in this manual.
Improper pump address set.
Ensure pump dip switches 3 and 4 are set properly for the installation. Both should
be OFF for use with Variable-Speed Controller or set to the proper address when
connected to an AquaLink RS controller, an AquaLink PDA, or an AquaLink Z4. See
Section 3.3, VS-FHP Pump Dip Switch Settings, in this manual. Note: VS-FHP 1.0
should always have dip switch setting 5 set to ON for both controllers.
Fault condition exists.
View fault message on controller and correct fault before proceeding. If unsure how
to correct fault, contact Zodiac Technical Support at 800.822.7933. In Canada, call
1-888-647-4004
ENGLISH
Possible Cause/Solution
RS controller, an AquaLink PDA, or an AquaLink
®
Technical Support at 800.822.7933. In Canada, call
®
Page 19