Troubleshooting; Before Calling For Service; Troubleshooting Guide - Franklin Chef FIM35 Manual Del Usuario

Ocultar thumbs Ver también para FIM35:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Before Calling for Service

If the unit appears to be malfunctioning, read through the OPERATION section of this
manual first. If the problem persists, check the Troubleshooting Guide below and on the
following page. The problem could be something very simple that can be solved without
a service call.
Problem
The ice maker is unplugged. Plug the ice maker in.
The fuse is blown.
The machine
The ice maker power
doesn' t operate.
switch is OFF.
The ice storage bin is full of
ice.
The drainage tray on top of
the compressor is full.
The water supply tap is
The water doesn' t
turned off.
feed in after the ice
The water supply line is not
maker starts.
connected properly.
Condenser may be dirty.
The air flow to the ice
Machine makes
maker may be obstructed.
ice, but ice storage
The ambient temperature
bin does not fill up
and water temperature are
with ice.
high, or machine is near
some heat source.
A few water drops fall to
the floor when you open the
door to take out ice from
Water is leaking
the ice storage bin.
from the unit.
Water supply connection
leaking.

Troubleshooting

Troubleshooting Guide

Possible Cause
24
Probable Correction
Replace fuse. If it happens again, call
for service to check for a short circuit
in the ice maker.
Turn the ice maker power switch to
ICE (ON).
Remove some ice; make sure the
ice-full probe is free of ice.
Drain off water by unscrewing lower
drainage nut.
Turn on the water supply tap.
Reconnect the water supply line.
Clean the condenser.
Check the installation.
Check the installation.
Normal condensation on the door or
some water together with ice. Take
care when you take out ice.
Tighten fitting. See "Connecting the
Water Line".