If your outlet looks like this:
4-wir_" r_'ceptacl_" (14-30R)
Then choose
a 4-wire
power
supply
cord with
ring or spade terminals
and UI. listed strain
relief. The 4-wire
power
supply
cord, at least 4 ft (1.22 m) long, must have four 10-gauge
copper
wires and match a 4-wire
receptacle
of NEMA Type 14-_¢0R. Fhe ground
wire (ground
conductor)
may be either
green or bare. The neutral
conductor
must be identified
by a white
cover.
If your outlet looks like this:
3-wire re'ceptacl_" (IO-30R)
Then choose
a 3-wire
power
supply
cord with
ring or spade terminals
and UL listed strain
relief. The 3-wire
power
supply
cord, at least 4 ft (1.22 m) long, must have three t0-gauge
copper
wires and match a 3-wire
receptacle
of NEMA
l_/pe 10-30R.
If connecting
by direct wire:
Power supply
cable must match power supply
(4-wire
or 3-wire)
and be:
[]
Flexible
armored
cable or nonmetallic
sheathed
copper
cable (with ground
wire/,
protected
with
flexible
metallic
conduit.
All current-carrying
wires must be insulated.
[]
10-gauge
solid copper
wire (do not use aluminum/.
[]
At least 5 ft (1.52 m) long.
GROUNDING
iNSTRUCTiONS
[] For a grounded,
cord-connected
dryer:
This dryer
must be grounded.
In the event of malfunction
or
breakdown,
grounding
will reduce
the risk of electric
shock
by providing
a path of least resistance
for electric
current.
This dryer
uses a cord
having
an equipment-grounding
conductor
and a grounding
plug. The plug must be plugged
into an appropriate
outlet
that is properly
installed
and
grounded
in accordance
with all local codes and ordinances.
[] For a permanently
connected
dryer:
This dryer
must be connected
to a grounded
metal,
permanent
wiring
system,
or an equipment-grounding
conductor
must be run with the circuit
conductors
and
connected
to the equipment-grounding
terminal
or lead on
the dryer.
WARNING:
Improper
connection
of the equipment-
grounding
conductor
can result in a risk of electric
shock.
Check
with a qualified
electrician
or service
representative
or personnel
if you are in doubt
as to whether
the dryer is
properly
grounded.
Do not modify
the plug on the power
supply
cord:
if it will not fit the outlet,
have a proper
outlet
installed
by a qualified
electrician.
SAVE THESE
INSTRUCTIONS