Installation
➤ Run the ducting to the other end, keeping it as straight, smooth, and taut as
possible.
➤ Remove excess ducting.
➤ Use the same connection method at the other end.
8.8
Control Panel Installation
Mind the following notes on the installation of the control panel (fig. 8 2,
page 6):
•
Mount the control panel (2) within 4.5 m of the electrical box (3).
•
Mount the control panel on an inside wall, slightly higher than mid-height of
the cabin, in a location with freely circulating air where it can best sense aver-
age temperature.
•
Do not mount the control panel
– in direct sunlight,
– near any heat producing appliances
– in a bulkhead where temperatures radiating from behind the panel may
affect performance
– in the supply-air stream
– above or below a supply or return-air grille
Before mounting the control panel, consider the location:
➤ Create a cut out size for the control panel:
64 mm (width) x 48 mm (height).
➤ Plug one end of the display cable (8-pin RJ-45 connector) into the display
socket J1 (fig. 0 4, page 8) of the electric box and the other end into the
back of the control panel.
➤ Remove jumper JP5 (fig. 0 14, page 8) of the electric box to activate
display.
➤ Prior to placement clean the mounting surface with isopropyl alcohol only
(test alcohol on hidden portion of surface first).
➤ Secure the control panel to a bulkhead with the adhesive strips provided.
22
MCS T6, MCS T12, MCS T16
EN