Operation

All connections to the terminal strip shall be made with appropriately sized
ring terminals (not supplied).
Each air conditioning unit installed requires its own dedicated circuit breaker.
– If there is only one air conditioning unit installed, the seawater pump
does not require a circuit breaker; the wiring from the seawater pump is
connected to the terminal strip on the unit (see wiring diagram, fig. 0,
page 8)
➤ Connect the air conditioning unit to the boat's bonding system to prevent
corrosion due to stray electrical current.
➤ Ensure that the AC ground of the air conditioning unit is properly connected
to the AC ground of the boat.
➤ Within the boat itself, ensure that the AC ground bus is connected to the DC
ground bus at exactly one place.
➤ Bond individually all pumps, metallic valves and fittings in the seawater circuit
that are insulated from the air conditioning unit by PVC or rubber hoses to the
boat's bonding system.
This will help eliminate any possibility of corrosion due to stray current.
10
Operation
I
NOTE
For operation see the Operating Manual.
11

Programming

I
NOTE
For programming and defining the parameters see the Operating Manual.
12

Troubleshooting Guidelines

I
NOTE
For troubleshooting see the Operating Manual.