Cleaning, maintenance and repair (Fig. 13, 14, 15)
CAUTION!
Risk of injury when cleaning or carrying out maintenance work due to
pressing the on switch unintentionally.
Therefore
– Comply with the safety instructions and always remove the battery before
Service addresses
Novopress GmbH & Co. KG
Scharnhorststr. 1
41460 Neuss
Germany
You can find the addresses of authorised specialist workshops by contacting Novopress or at
www.novopress.de.
Service intervals
Service and repair work may only be carried out by Novopress or the authorised Novopress
specialist workshops.
Information!
The next service is stated on the press device and the press collar.
This service must be performed at least once a year. If more than 2500 pressing
operations are carried out in a year, a service must be performed after these 2500
operations, at the latest.
An LED indicates that the service interval is expiring 100 pressing operations in
advance (see Section 7.1 Meaning of the LED display).
Regularly (before use, at the start of the working day) and when soiled
(Fig. 13)
• Check the press collar, adaptor jaw and device for visible defects such as damage,
material cracks and other signs of wear. If defects are found, do not use the device any
more. Replace it or send it to an authorised specialist workshop.
• Clean the press collar with compressed air.
• Lubricate the adaptor jaw pins.
• Spray the entire adaptor jaw with lubricant.
• Remove deposits from pressing contour (K).
• Clean press collar pressing contour (K).
• Completely coat pressing contour (K) with lubricant.
• Check that sliding segments (C) and shells (D) can move freely.