Set Master Valve Or Pump; Set Rain Delay; Turning The Controller Off - Nelson EZ PRO Serie Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
PROGRAMMING INSTRUCTIONS

Set Master Valve or Pump

You can turn on or off the Pump or Master valve output by zone with the EZ Pro™. Turn the
large dial to the MV/PUMP position. Use the SELECT
ADJUST
to turn the MV/ PUMP output on or off when that zone is running. The LCD will
show the zone number and either on or off. When watering the zones selected off will not run
the MV/ PUMP.
Set a Rain Delay
If you wish to suspend watering for a specified time (from 1-99 days) due to rainy weather or
other conditions, the EZ Pro™ has this option. A Rain Delay can be programmed for Program
A, B, C, Programs AB, BC, AC or ABC. Turn the large dial to the RAIN DELAY position. The
LCD will display the RAIN DELAY arrow and the days of delay. Use the SELECT
choose one of the following; Program A, B, C, Programs AB, BC, AC or ABC. Use the
ADJUST
to choose the number of days from 1-99 to suspend watering. Turn the MODE
dial back to AUTO. After the specified period (from 1-99 days) the EZ Pro™ will return to
automatic watering at the next programmed start time. During any delay period the RAIN
DELAY arrow will blink.

TURNING THE CONTROLLER OFF

Turn the MODE dial to the OFF position. This suspends all watering operations (including
manual/test procedures) from operating. The clock continues to maintain the current time and
date and your program(s) is retained until you want to run your program(s) again. To run your
program, turn the MODE dial back to the AUTO position.
NOTE:
The non-volatile memory of the EZ will maintain your program without
power. If a battery is not present and AC power is lost, the real time for the
clock will be lost. The time will need to be reprogrammed.
keys to choose the zone. Use the
to
18

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido