Assembly; Startup - AL-KO HW 5000 FMS Premium Manual De Instrucciones

Ocultar thumbs Ver también para HW 5000 FMS Premium:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45

Assembly

The unit must only be operated with an
electrical installation in accordance with DIN/
VDE 0100, Part 737, 738 and 702 (swimming
pools). Protection must be provided by a 10 A
line protection switch and a RCCD (residual
current operated device) having a nominal re-
sidual current of 10/30 mA.
Use only extension cables that are suitable
for use outdoors - minimum cross-section 1.5
mm
. Cable drums should always be unrolled
2
completely.
Damaged or brittle extension cables must not
be used.
Check the condition of your extension
cable each time you start to use the
equipment.
ASSEMBLY
Erecting the equipment
1. Prepare a flat and solid erection site.
2. Erect the machine horizontally and protected
against flooding.
3. Bolt the house water system securely at the
bolting points (Fig. A -7) if necessary.
4. The house water system must be protected
from rain and direct water jets.
In daily operation (automatic mode), you
ADVICE
must ensure, by suitable measures, that,
in the event of a fault in the equipment,
consequential damage caused by floo-
ding is excluded.
Connecting the suction line
1. Select the length of the suction line (Fig. B
-17) to make sure that the house water sys-
tem cannot run dry. The suction line must al-
ways be at least 30 cm under the surface of
the water.
2. Connect the suction line. Make sure that the
connection is tight, but do not damage the
thread.
We recommend using flexible lines at the
pump inlet (Fig. A -10). This ensures that
pressure or tension on the house water
system cannot be exerted.
3. If the water has a small amount of sand in it,
a pre-filter must be fitted between the suction
line and the pump inlet. Ask your expert dea-
ler about this.
467 777_a
4. Always lay the suction line with an upward
gradient.
If the suction height is more than 4m, you
ADVICE
must use a suction hose having a diame-
ter greater than 1". We recommend the
use of an AL-KO suction unit with suction
hose, suction filter and flow-back stop.
Ask your expert dealer.
Fitting the pressure line
1. Screw the connecting nipple (Fig. B -15) with
the round seal ring (Fig. B -16) into the pump
outlet (Fig. A -4).
2. Screw the elbow nipple (Fig. B -13) with seal
(Fig. B -14) onto the connecting nipple (Fig. B
-15) and turn the elbow nipple in the desired
direction.
3. Fix a pressure line (Fig. B -11) onto the elbow
nipple (Fig. B -13).
4. Open all the closing off devices (valves, spray
nozzles, water cock) in the pressure line.

STARTUP

On initial commissioning the display
ADVICE
shows (Fig. E -29) all information in
English. Select the desired language
with the MODE button (-30) and confirm
with the SET button (-31) . The air pres-
sure in the storage vessel can now be
checked.
Check the air pressure in the storage vessel
CAUTION!
Operation is not possible under an air
pressure of 1.4 and over 1.9 bar. The
pump does not start.
1. Unplug the mains plug on the pump.
2. Slide the closing off cover valve (Fig. D -27)
on the back of the storage vessel (Fig. A -6)
upwards.
3. Check the air pressure at the valve (Fig. D
-28) with an air pump or a tyre filler, each ha-
ving a pressure indicator.
4. Then close the closing off cover valve on the
back of the storage vessel again.
5. Replace the mains plug.
The house water system can now be
commissioned.
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hw 6000 fms premium112 851112 852

Tabla de contenido