6.2 Generation of a new radio control code
The radio control is supplied with a function intended to self-generate a new code. If you press the power on/off buttons
and hold them down for at least 10 sec,, the red LED will turn fixedly on. If you release and press the same buttons again,
the radio control will random-generate the new code. The red led will flash on and off for 4 times consecutively before
turning off. To use the "re-programmed" radio control, repeat the acquisition procedure described before.
14 MAINTENANCE (See the drawing C)
The two filters must be replaced periodically, or when dirty or clogged. They are placed one in the front area and one in the
back area of the machine. They can be easily extracted from the central hole by using two fingers. The new filters must be
put back by following the same procedure and making them adhere to the hole inner surface. Their clogging impairs the
motor good functioning. If they are not replaced, the motor can even burn (thus making the warranty expire).
15 SPARE PARTS
- Air suction filter. Code FIL03. (See the drawing C)
- 3m. hose with two connections. Code ATC03 only for TMR55 and TMR80 models.
- 7m. hose with two connections. Code ATC04 only for TMR140 model.
- 3m. hose with two connections. Code ATC07 only for TMR90E model.
- 7m. hose with two connections. Code ATC08 only for TMR150E and TMR180E models.
16 SPRAY GUNS AND OPTIONAL COMPONENTS
See the booklet.
17 TECHNICAL DATA
TMR55
Motor type
double insulation
Supply voltage
*230 V, 50Hz
Electric power
550W
absorbed
Fan group
Two-stage
Quantity of air
1800 l/min.
delivered
Pressure
0,13 bar
Operating
from -10°C
temperature
to +40°C
Air delivery hose
3m
Electric wire
7m
Size
300x220x310
Weight
4,8 Kg
*Voltage of about 110V, 50Hz on request
**With air flow adjuster
18 SUGGESTIONS IN CASE OF MALFUNCTIONING
Problem
The turbine does not start
The air flow is too high and/or low
The turbine makes noise
Radiocomando non funziona
TMR80
TMR140
double insulation
double insulation
*230 V, 50Hz
*230 V, 50Hz
800W
1400W
Two-stage
Three-stage
450-2100 l/min.
560-2200 l/min.
**0,02-0,18 bar
**0,02-0,32 bar
from -10°C
from -10°C
to +40°C
to +40°C
3m
7m
7m
7m
300x220x310
300x220x310
5 Kg
6 Kg
Probable cause
- There is no current.
- The turbine switch, cable or plug are damaged.
- The switch light and control panel led will not
turn on
- The air filter is dirty.
- The air delivery hose is damaged.
- The air delivery hose has not been
tightened in the correct way.
- The motor is damaged.
- New radio control
- Exhausted batteries
- Radio control damaged
- 11 -
TMR90E
TMR150E
double insulation
double insulation
*230 V, 50Hz
*230 V, 50Hz
900W
1500W
Two-stage
Three-stage
850-2000 l/min.
1050-2200 l/min.
**0,04-0,19 bar
**0,08-0,34 bar
from -10°C
from -10°C
to +40°C
to +40°C
3m
7m
7m
7m
300x220x310
300x220x310
5.3 Kg
6.3 Kg
Rimedio
- The plug is not connected to the net;
- Check the net voltage.
- Check the switch, the cable and the plug;
- Call the Customer Care Technical Service.
- Contact the after-sales service
- Replace the air filter.
- Call the Customer Care Technical Service.
- Check the air delivery hose tightening.
- Call the Customer Care Technical Service.
- Set the radio control according to instructions
- Replace batteries and set the radio control
- Replace the radio control
EN
TMR180E
double insulation
*230 V, 50Hz
1800W
Three-stage
1100-2500 l/min.
**0,10-0,44 bar
from -10°C
to +40°C
7m
7m
300x220x310
6.7 Kg