Comunello Automation QUAD - 230V - HP Instrucciones De Uso página 40

Tabla de contenido

Publicidad

• Send the selected code with the remote control;
• The LED L2 will remain steady on for a second to indicate that
programming has been completed;
• The LED L2 starts to blink again to indicate that you have 10 additional
sec. to store a new code;
• On expiry of those 10 sec.the LED L2 will remain steady on.
Remote control code programming of the partial / pedestrian opening
(Mot. no. 1):
• By the key SELECT, position yourself on the blinking LED L2 "CODE TX";
• Press key SET twice to memorize the PPED channel and the led will
modify its blinking (110110110);
• Send the selected code with the remote control;
• The LED L2 will remain steady on for a second to indicate that
programming has been completed. The extra time of 10 sec. to store a
new PPED channel is then preview as for the PP channel.
Remote control code programming of the 2nd AUX channel:
• By the key SELECT, position yourself on the blinking LED L2 "CODE TX";
• Press key SET 3 times to memorize the 2nd auxiliary channel and the
led will modify its blinking (1 1 1 0 1 1 1 0);
• Send the selected code with the remote control;
• The LED L2 will remain steady on for a second to indicate that
programming has been completed.
• The extra time of 10 sec. to store a new AUX channel is then preview as
for the PP channel.
Important note: If a code has already been entered or all 120 codes
have been memorized, by repeating the programming operation, all the
programming LEDs will start to flash, indicating that no further storing is
possible.
Deletion of remote control codes:
• By the key SELECT, position yourself on the blinking LED L2 "CODE TX";
• Activate the blinking of the code to be deleted (P.P., PED. or AUX,
indicated by the respective blinking);
• Press and hold down key SET for more than 5 sec.;
• The LED switches off for 2 sec. and the procedure is completed;
• If the CODE, PEDESTRIANS, or AUX codes are deleted, the LED will
remain off.
Important note: If both channels codes are deleted, the LED will remain off,
by the contrary if only PEDESTRIAN codes remain stored, the LED blinking
mode will change (1 1 1 1 0 1 1 1 1 0).
Rule of the first saved Remote control:
When programming remotes the following rule is applied:
if the first remote to be saved is a rolling code type, the receiver will
subsequently accept only rolling code remotes (thus providing enhanced
anti-intrusion security); if the first remote to be saved is a fixed code type,
the receiver will subsequently accept both fixed code remotes and rolling
code remotes, although only the fixed part of the latter will be controlled
(thus effectively relinquishing the security of the rolling code system).
8.1.3. LED L3 - CONDO: "Condominium" logic:
The enabling of the Condominium function means that during the opening
movement or during the pause time the control unit will not respond to
commands sent by Pushbuttons or remotes.
In contrast, during the closing movement a command sent by the
Pushbuttons or the remotes will reverse the direction of movement. This
operating mode is invaluable when the automation includes a loop detector.
In the default configuration the control unit is set with the Condominium
function disabled; if the Condominium function is required, proceed as
follows:
• By the key SELECT, position yourself on the blinking LED no.3;
• Press the SET key;
• LED L4 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.1.4. LED L4 - MOTOR TIME: Programming of the motors stroke (max
4 min.)
It is necessary to program the working time of the motors
To set a new stroke, programming must be carried out with leaves in closed
position as follows:
• By the key SELECT, position yourself on the blinking LED no.4;
• Press the SET key; · Motor no.1 starts the opening phase;
• At the desired initial deceleration point, press the SET key again, LED L4
40
COMUNELLO ®Copyright 2019 - All right reserved
will start to flash more slowly and Motor 1 will decelerate;
• When the desired position is reached, press the SET button to end the
Opening cycle;
• LED L4 will now resume flashing normally and Motor 2 will begin
Opening;
• Repeat the work time programming procedure for Motor 2;
• Once programming of the motor Opening times has been completed,
Motor 2 restarts Closing immediately: repeat the above procedures for
the Closing phase of Motor 2 and subsequently Motor 1.
If you wish to exclude the slowing down (strongly advised against), when
opening, wait until you reach the fully open position and proceed as
follows:
• In the case of motors with encoders and / or electric limit switches,
press the SET key once and the reclosing phase will start;
• In the case of motors without an encoder and / or electrical limit switches,
press the SET key twice and the closing phase will begin."
Important notes:
- If you do not require the control unit to perform the deceleration, during
programming, when the open-close cycle has been completed press the
SET key twice consecutively rather than just once.
- If the control unit is used in the 1 Motor configuration (dip 1 of SW1 OFF),
the programming of the working time of the Motor 2 is not performed
- During programming, instead of the SET key on the control unit you can
use the button on the remote already stored.
8.1.5. LED L5 - PAUSE TIME Automatic closing time programming:
The control unit is factory set with automatic closing disabled.
If you wish to enable automatic closing proceed as follows:
• By the key SELECT, position yourself on the blinking LED no.5;
• Press the SET key;
• Wait for a time equivalent to the desired time interval (from 1 sec. up to
4 min.);
• Press the SET key again momentarily and at the same time the automatic
closing time will be saved and LED L5 will remain steady on;
If you wish to restore the initial condition (no automatic closing)
• select blinking LED L6.
• press the SET key twice consecutively in a time period of 2 seconds.
• The LED will switch off and the operation will be completed.
During programming, instead of the SET key on the control unit you can use
the button on the remote, providing the remote has been saved beforehand.
8.1.6. LED L6 - LEAVES DELAY:
The control unit is factory set with 4 Sec. leaves opening and closing delay.
Proceed as follows if you wish to modify that period:
• By the key SELECT, position yourself on the blinking LED L6;
• Press the SET key;
• Wait for a time equivalent to the desired time interval for leaves delay in
the closing phase (from 4 sec. up to 15 min.);
• Press the SET button again for an instant, thus determining the door
delay time to be memorised (during opening it is fixed at 4 seconds,
whereas it will be the gate delay closing time for the programmed time);
• LED L6 becomes steady on and programming will be completed: the
delay time is fixed for opening leaves at 4 sec and it is up to 15 sec for
closing leaves
If you want to deactivate this function (without leaves delay),
• select blinking LED L6
• press the SET key twice consecutively in a time interval of 2 seconds,
at the same time the LED will switch off and the operation will be
terminated.
8.1.7. LED L7 - AUTOMATIC PROGRAMMING:
"
The control unit allows to carry out an Automatic Programming (SIMPLIFIED
and only in the presence of encoders and / or electric limit switches) to
automatically adjust stroke and slowdowns of the leaves. To set a new
stroke, programming must be carried out with leaves in intermediate
position (partially open) as follows:
• Position the actuators manually until half of the stroke before continuing.
• By the key SELECT, position yourself on the blinking LED no.7;
• Press the SET key;
• To determine its zero position, Motor no.2 performs its closure until it
reaches the limit switch or mechanical stop;
• Afterwards the same operation will be repeated by the Motor no. 1;
• The control unit executes the Auto programming procedure by

Publicidad

Tabla de contenido
loading

Tabla de contenido