8.4 EXTENDED MENU 3
The control unit is factory set to allow direct selection exclusively of the main
menu functions.
If you wish to enable the functions described in Extended Menu 3, proceed
as follows:
• Select blinking LEV LED
• press SET 3 times
• The led will start blinking (alternate flashing of the LEV LED
There will be 30 seconds to select the functions of the Extended Menu
3 using the SELECT and SET keys; once an additional 30 seconds have
elapsed the control unit reverts to the main menu.
ID
REFERENCE LED
L1
SOFT STOP
ON
L2
SOFT START
ON
L3
RELEASE STROKE
ON
L4
SLAM LOCK
ON
L5
ELS / CMD PED
ON
LAMP / L.CORT / INDICA-
L6
ON
TOR L
L7
PRELAMP / LAMP IN PAUSE
ON
LEV
MENU LEVEL
8.4.1. LED L1 - SOFT STOP:
The control unit is supplied by the manufacturer with the Soft Stop function
disabled. To enable the function, proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L1;
• Press the SET key;
• LED L1 becomes steady on and programming will be completed.
In this way, during door movement, when a PP/DS1/DS2/DS3 command is
sent, the speed will gradually be brought to zero (within 2 seconds).
Repeat the procedure if you wish to restore the previous configuration.
Notes:
- Soft-stop is not operated when a limit switch is triggered, when the Stop /
safety edge button is activated and in case of an obstacle.
8.4.2. LED L2 - SOFT START:
The control unit is supplied by factory with the Soft Start function disabled.
With this function enabled at the beginning of the movement the speed
gradually increase from the minimum to the value set by the "SPEED"
trimmer during the first 2 seconds of operation.
Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L2;
• LED L2 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
Important note: when the Soft Start function is enabled, the control unit
automatically disables the Starting Torque function, while if Soft Start is
disabled then Starting Torque is automatically enabled.
8.4.3. LED L3 - RELEASE STROKE (in opening phase):
The control unit is supplied by factory with the release stroke function
disabled. This function consists of sending a closing command for 2
seconds before starting the opening stroke: in this way the release of
the lock is facilitated to allow the correct execution of the opening phase.
Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L3;
• Press the SET key;
• LED L3 becomes steady on and programming will be completed.
If you wish to enable the function at the power level set by the FORCE
trimmer, repeat the above mention programming, by pressing SELECT
twice (obtaining fast flashing of LED L3 instead of once) and then press
SET.
Repeat the procedure if you wish to restore the previous configuration.
8.4.4. LED L4 - SLAM LOCK: (in closing phase):
The control unit is supplied by factory with the Slam lock function disabled.
This function consists in adding, in the presence of a deceleration stage
during closing, a stroke lasting 1 second at the maximum power or at the
).
power selected with the "FORCE" trimmer, in such a way as to ensure
positive engagement of the gate lock, if installed. If you wish to enable the
Slam Lock function at maximum power, proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L4;
• LED L4 becomes steady on and programming will be completed.
If you wish to enable the function at the power level set by the FORCE
OFF
trimmer, repeat the above mention programming, by pressing SELECT
OFF
twice (obtaining fast flashing of LED L4 instead of once) and then press SET.
OFF
Repeat the procedure if you wish to restore the previous configuration.
OFF
8.4.5. LED L5 - ELECTRICK LOCK ACTIVATED BY DISABLED PED.
OFF
BUTTON:
The control unit is factory set with the function for electric lock activation
OFF
via the Pedestrian command disabled. The function for electric lock
activation with the Pedestrian command is used when, for example, the
OFF
application consists of a sliding gate with a pedestrian gate alongside.
With this function enabled the sliding gate can be opened both using
3 FLASHING
commands from the P/P Pushbutton and the remotes, and via the PED
commands from the pedestrian gate by activating the electric lock.
To enable this function proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L5;
• LED L5 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.4.6. LED L6 - FLASHING LIGHT / INDICATOR LIGHT / COURTESY
LIGHT:
By activating this function it is possible to change the indicator light (it does
not flash during the pause), while the flashing output becomes a courtesy
light. To enable this function proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L6;
• LED L6 turns on (fixed) and programming will be completed (the LED
doesn't light up, but is enabled).
Repeat the procedure if you wish to restore the previous configuration.
Courtesy Light Operation: The 24 ~ 4W max. Courtesy Light output will
switch on for 3 minutes whenever an opening command is transmitted.
8.4.7. LED L7 - PRE-FLASH/FLASH IN PAUSE:
The control unit is supplied by the factory with the Pre-flashing and Flashing
during Pause (3 sec. pre-flash before closing phase) both disabled.
Pre-flashing operation: The 24V flasher output will always be activated 3
seconds before the closing manoeuvre. If Pre-flashing operation is required,
proceed as follows:
Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L7;
• LED L7 becomes steady on and programming will be completed.
• Flashing operation during the Pause: The 230 Vac and 24V flashing light
output will remain active if the pause time is previously programmed. If
you wish to enable this function, repeat the operation described above,
pressing the SELECT key twice (obtaining the fast flashing of the L7
LED) and then press SET. The L7 LED will remain on steady.
Repeat the procedure if you wish to restore the previous configuration.
9 RESET
If the factory settings of the control unit need to be restored, press the
SELECT and SET button simultaneously for about 5 seconds, at the same
time, all RED indicator LEDs will simultaneously turn on, with subsequent
immediate shut-down.