Troubleshooting

Compressor does not run (battery connection)

Fault
U
= 0 V
Term
≤ U
U
KL
ON
Start attempt with
U
≤ U
Term
OFF
Start attempt with
U
≥ U
Term
ON
Electric circuit between
the pins in the compres-
sor interrupted
U
Voltage between the positive and negative terminals of the electronics
Term
U
Cut-in voltage of the electronics
ON
U
Cut-off voltage of the electronics
OFF
28
Possible cause
The connection between the battery
and electronics unit has been inter-
rupted.
Main switch faulty (if installed)
Additional supply line fuse has blown
(if installed)
Battery voltage is too low
Loose cables
Poor contact (corrosion)
Battery capacity too low
Cable cross section too small
Ambient temperature too high
Insufficient ventilation
Condenser is dirty
Defective compressor
CRX1050, CRX1065, CRX1080
Remedy
Establish a connection
Replace the main switch
Replace the supply line
fuse
Charge the battery
Establish a connection
Replacing the battery
Replace the cable
(fig. a, page 7)
Move the refrigerator to a
different position
Clean the condenser
Replace the compressor