Exit programming mode
To leave programming mode, type
5.6
Operation
This system is designed with "FORCED TO ARM" operation. If faulty zones exist it will bypass the
faulty zones automatically after it is armed. The LED of the faulty zones will flash to indicate that
they are not protected and the "FORCED TO ARM" LED will also flash to indicate that the system is in
"Forced To Arm"-mode with the faulty zones bypassed.
a. Arm the system with exit delay
Make sure that the alarm system is in disarmed mode and the alarm memory is empty. If the
memory is not empty, clear it first (see below).
Enter an appropriate USER CODE and validate with
2-beeps confirm correct code entry, exit delay starts and EXIT/ARMED LED flashes.
5-beeps indicate incorrect code entry. Enter the code again.
System will arm after exit delay expires. The appropriate partition LED and the EXIT/ARMED LED
are ON.
b. Arm the system instantly
Make sure that the alarm system is in disarmed mode and the alarm memory is empty. If the
memory is not empty, clear it first (see below).
Enter an appropriate USER CODE,
2-beeps confirm correct code entry and the system arms instantly without exit delay. The
appropriate partition LED and the EXIT/ARMED LED are ON.
5-beeps indicate incorrect code entry. Enter the code again.
Note: as there is no exit delay, walking through the protected area will trigger the alarm. Mount
the keypad outside the protected zone to use this function.
c. Arm the system in home mode with exit delay
This function only works with USER CODE 3. The protection zones that are stored in memory
will be bypassed when arming.
Enter USER CODE 3,
2-beeps confirm correct code entry, exit delay starts and EXIT/ARMED LED flashes.
5-beeps indicate incorrect code entry. Enter the code again.
The LEDs indicating the bypassed zones will flash constantly.
System will arm after exit delay expires. The appropriate partition LED and the EXIT/ARMED LED
are ON.
Note: in HOME mode, USER CODE 1 and 2 can still be used to disarm the partitions.
d. Arm the system in home mode instantly
This function only works with USER CODE 3. The protection zones that are stored in memory
will be bypassed when arming.
alarms.
Enter USER CODE 3,
2-beeps confirm correct code entry and the system arms instantly without exit delay.
e. Arm the system with manual bypass
This function allows the temporary bypassing of protection zones, e.g. faulty zones.
USER CODE 1 can only bypass zones in partition 1 while USER CODE 2 can only bypass zones
in partition 2. With USER CODE 3, all zones can be bypassed.
Make sure that the alarm system is in disarmed mode and the alarm memory is empty. If the
memory is not empty, clear it first (see below).
Enter the appropriate USER CODE,
.
2-beeps confirm correct code entry, exit delay starts and EXIT/ARMED LED flashes.
5-beeps indicate incorrect code entry. Enter the code again.
The LEDs indicating the bypassed zones will flash constantly.
00 (10/10/2008)
HAM263D
.
,
and
.
The bypassed zones are not monitored and will not trigger alarms.
and
.
The bypassed zones are not monitored and will not trigger
,
and
.
, the zone numbers that need to be bypassed
17
key.