Velleman HAM263D Manual Del Usuario página 5

Ocultar thumbs Ver también para HAM263D:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1
AC in
AC Power input from a 16.5VAC, minimum 1.5A, 50~60Hz transformer. The primary
2
side of the transformer must be connected to an un-switched receptacle.
The used transformer must comply with the EN61558 standard for European
countries.
3
DC out
Un-switched +12VDC output power referring to the common ground. Continues
output, not depending on the arm/disarmed status. Can be used for devices requiring
uninterrupted power supply e.g. smoke detectors, control keypads etc. This output
has a 750mA resettable fuse.
4
GND
Common Ground (-)
5
DC out
Continuous +12VDC output power under normal condition (no alarm). The output is
switched OFF at alarm condition; it has a 2.5A resettable fuse. Suitable for the
connection of satellite siren/strobe light with internal battery.
6
DC out
Continuous +12V output power under alarm condition until the system is disarmed.
The output has a 2.5A resettable fuse. It is mostly suitable for providing power for the
stand alone strobe light or those devices require continuous operation at alarm
condition after the siren timer is reset (e.g. SV/PSL3).
7
DC out
+12V output power under alarm condition with the duration depending on the
setting of the alarm timer; it has a 2.5A resettable fuse. Can be used for electronic
siren or alarm bell.
The following 4 contacts are dedicated for the connection of one or more
HAA263D, HAA85WP... The total number of keypad(s) and key switches however is limited to four.
8
GND
Common Ground (-) for keypad(s)
9
CLK
Clock wire
10 Data
Data wire
11 DC out
+12V output power common point with a 750mA resettable fuse for keypad(s) and
key switches.
• The following 5 contacts are for inputs from key switches, e.g. HAA80MK.
12 Part 1 ON/OFF
13 Part 2 ON/OFF
14 Part 1 status
15 Part 2 status
16 System status
Note that contacts 12 and 13 can be connected together to one key switch to arm or disarm
partition one and two simultaneously.
• The following 12 contacts are for the connection of sensor inputs e.g. PIR detectors (HAA52N),
magnetic contacts (HAA25, HAA27) panic buttons (HAA60) ... They represent zone 1 to 8 and their
common groundings. The zones are End of Line (E.O.L.) monitored by a 2.2KΩ resistor.
• All normally closed (N.C.) contacts are to be wired in series with the E.O.L. resistor, where all
normally open (N.O.) contacts are to be wired in parallel with the E.O.L. resistor.
00 (10/10/2008)
for keypad(s)
for keypad(s)
Arm/disarm partition 1: accepts normally open (N.O) momentary switches.
Multiple switches can be connected in parallel.
Arm/disarm partition 1: accepts normally open (N.O) momentary switches.
Multiple switches can be connected in parallel.
LED indication partition 1: show zone status of partition 1.
LED indication partition 2: show zone status of partition 2.
LED indication system: show zone status of entire system.
HAM263D
1. N.C. contact
2. N.O. contact
3. 2.2KΩ E.O.L. resistor
5
digital keypads, e.g.
VELLEMAN

Publicidad

Tabla de contenido
loading

Tabla de contenido