Descargar Imprimir esta página

SICK PLS Serie Manual Del Usuario página 184

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
PLS
Properties
Time behaviour of output
without restart inhibit
Deactivation after WF incursion
(double-speed scanning)
Activation on warning field (WF) clear
Time behaviour of output
with restart inhibit
Deactivation after WF incursion
(double-speed scanning)
Activation on warning field (WF) clear Restart necessary
Time behaviour of output
after n seconds
Deactivation after WF incursion
(double-speed scanning)
Activation on warning field (WF) clear
Short-circuit protected
Switching frequency
Load inductivity
Safety outputs (OSSD)
- dynamic (HIGH active)
Switching voltage
HIGH active (Ueff)
184
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
min.
Deactivation depends on scan
rate, activation does not.
Depends on scan rate
Depends on scan rate
8 008 321/M844/06-05-02 Operating Instructions • PLS
GB
Data
type
max.
127 ms
40 ms
127 ms
127 ms
40 ms
Yes
3 Hz
2 H
Uv - 2.5 V