PLS
Properties
Measuring error ≤ 2 m range
Measuring error ≤ 4 m range
General data
Electrical connection
Interface
If you are terminating the cables your-
self, take care to connect the cable
screening. We recommend connecting
the screening at both ends if using
an RS232 connection.
If using an RS422 connection, the
screening should be connected at one
end only. The screening should be
installed at the computer end
(or at the LSI end).
Transfer rate
RS 232
RS 422
continuous computer link only
permissible with RS 422
Cable length
RS 232
RS 422
Scan rate
Restart after n seconds
Laser protection class
188
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
min.
Plug-in connector housing,
threaded for 0.5 mm
crimp connection, PG 9
Universal (RS 232 / RS 422)
9600 baud
9600 baud
2
2
8 008 321/M844/06-05-02 Operating Instructions • PLS
GB
Data
type
max.
± 94 mm
± 131 mm
2
56 kbaud
500 kbaud
15 m
100 m
16
60
1