Maintenance And Care - Echo DHC-200 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1. Bolt
Lubricating gear housing
1
1. Grease fitting

Maintenance and care

Cutter blade adjustment
Standard blades require no periodic adjustments. Make sure all
blade bolts are tight and in good condition.
Tools required:
Grease gun, Rag.
Parts required:
Lithium based grease.
1.
Clean dirt from grease fitting.
2.
Hold the product firmly and carefully pump grease in fitting.
Do not force grease. Too much pressure will force grease
past seals and cause damage. Apply 1 - 2 pumps of
grease every 15 - 20 hours of operation.
NOTE
Use good quality lithium multi grease.
21

Publicidad

Tabla de contenido
loading

Tabla de contenido