6.2
Height Difference and Reduced Level Measurement (internal Memory not
active)
dH
MEAS
100.038m
BM:
: >>>>
Meas Reference
: >>>>
To change BM & RflD
goto nenue
Measure to Bench-
Measuring in
mark with prompt
progress
message
dH
MEAS
Elv:
Meas.Target !
dH:
:
>>>>
:
>>>>
Prompt message
Measuring in
measure to target
progress
Operation
dH
Step Key/Screen Description
1.
1.235
:
m
:
5.68
m
2.
Measurement to
Benchmark
3.
displayed
dH
Elv:
4.
99.138 m
dH:
- 0.900 m
:
2.135 m
:
5.
31.11 m
Measurement to
target displayed
6.
10
Press key to start height difference and
reduced level function.
A message "Meas. Reference" with input
reduced level is displayed.
Press measuring key to initiate measurement
with respect to the Reference staff / Bench-
mark.
Reference height and distance measurement
is displayed; follow by a message "Meas.
Target!" prompted.
Again, press measure key to start measure-
ment with reference to target point.
The following results are displayed accord-
ingly;- target reduced level (RL), target height
difference (dH) with respect to the reference
staff, height and distance of target point.