SPECIFICATIONS
Model
Voltage*
Power input*
No load speed
Steel
Capacity
Wood
Weight (without cord)
Spec. for keyed chuck
Spec. for keyless chuck
* Be sure to check the nameplate on product as it is subject to change by areas.
NOTE
Due to HiKOKI's continuing program of research and development, the specifi cations herein are subject to change
without prior notice.
MOUNTING AND OPERATION
Action
Mounting stopper assembly
Mounting and dismounting the bit*
Switch operation
Locking-on the On / Off switch
Releasing the On / Off switch
Selecting accessories
* 1 Selecting the appropriate drill bit
(1) When drilling holes in metals or plastics:
Use ordinary metalworking drill bits;
Applicable drill sizes range from 0.5 mm min. to 6.5 mm
max.
(2) When drilling holes in lumber:
Use woodworking drill bits.
For small holes of 6.5 mm dia, or less, use metalworking
drill bits.

MAINTENANCE AND INSPECTION

CAUTION
Be sure to switch power OFF and disconnect the plug from
the receptacle during maintenance and inspection.
1. Inspecting the drill bits
Since use of an abraded drill bits will cause motor
malfunctioning and degraded effi ciency, replace the drill
bits with a new one or resharpening without delay when
abrasion is noted.
2. Inspecting the mounting screws
Regularly inspect all mounting screws and ensure that
they are properly tightened. Should any of the screws be
loose, retighten them immediately. Failure to do so could
result in serious hazard.
3. Servicing
Consult an authorized Service Center in the event of
power tool failure.
CAUTION
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
Figure
Page
1
47
1
2
47
3
47
4
47
5
47
48
D6SH
(110 V, 220 V, 230 V, 240 V)
240 W
4500 min
-1
6.5 mm
9 mm
0.9 kg
1.0 kg
GUARANTEE
We guarantee HiKOKI power tools in accordance with
statutory/country specifi c regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the power tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling instruction,
to a HiKOKI Authorized Service Center.
IMPORTANT
Correct connection of the plug
The wires of the main lead are coloured in accordance with
the following code:
Blue:
— Neutral
Brown: — Live
As the colours of the wires in the main lead of this tool may
not correspond with the coloured markings identifying the
terminals in your plug proceed as follows:
The wire coloured blue must be connected to the terminal
marked with the letter N or coloured black. The wire
coloured brown must be connected to the terminal marked
with the letter L or coloured red. Neither core must be
connected to the each terminal.
NOTE:
This requirement is provided according to BRITISH
STANDARD 2769: 1984.
Therefore, the letter code and colour code may not be
applicable to other markets except The United Kingdom.
Information concerning airborne noise and vibration
The measured values were determined according to
EN60745 and declared in accordance with ISO 4871.
Measured A-weighted sound power level: 86 dB (A).
Measured A-weighted sound pressure level: 75 dB (A).
Uncertainty K: 3 dB (A).
Wear hearing protection.
Vibration total values (triax vector sum) determined
according to EN60745.
Drilling into metal:
Vibration emission value
Uncertainty K = 1.8 m/s
4
D6SB
3000 min
-1
6.5 mm
13 mm
a
h , D = 5.7 m/s
2
2