EN – Installation instructions
The radiator may only be installed by a special-
ist.
Safety instructions
Read these instructions thoroughly prior to
installation/commissioning.
After installation, pass the instructions on
to the end user.
WARNING
Risk of injury!
Note the weight of the radiator (see
manufacturer's data).
At 25 kg and above, the work should be
carried out with lifting equipment or by
several persons.
Conditions of use
Observe the operating conditions for wa-
ter heating installations as defined in
DIN  18380 "VOB German Contract Proce-
dures for Building Services".
Maintain water quality as defined in VDI
2035 "Prevention of damage in water heat-
ing installations".
Observe the limitations for use in damp
rooms as defined in DIN  55900 "Coatings
for radiators".
Use radiator only in closed heating systems.
Store and transport radiator only in the
protective packaging.
Observe minimum clearances between ra-
diator and surrounding objects for air cir-
culation.
Complaints
Please contact the supplier.
Disposal
Packaging and any parts that are not need-
ed should be recycled or disposed of prop-
erly. Observe local regulations.
Technical features
Operating pressure: max. 10 bar
Test pressure: 1.3 x operating pressure
Flow temperature: hot water up to
110°C (230°F)
Directions for installation
Protect radiator from damage
When installing, only remove protective
packaging at the fastening and connection
points.
Only remove protective packaging com-
pletely during final cleaning or prior to
commissioning.
Fixing
For radiators with lugs: Note the number
and positions of fixing points (see Fig. A).
Install mounting material according to
separate installation instructions.
Compact radiator connection
Unscrew painted blanking plugs at the des-
ignated connection points.
Note: Do not install Therm X2
plugs in radiators with a height of 200.
For multilayered radiators and twinwire or
alternating connection: Install accompany-
ing Therm X2
separating plugs (see sepa-
®
rate installation instructions).
Connect radiator with commercially avail-
able fittings upstream.
Tightly cap open connections with air vent
plugs (top) and blanking plugs.
Only existing blanking plugs may be used on
Kermi steel panel radiators.
Valve radiator connection
Valve with factory pre-set k
facturer's data).
Air vent plugs (top) and blanking plugs are fac-
tory pre-assembled.
Remove painted caps on the valve mount-
ings and dispose of, as they must not be
used as seals on the radiator.
Connect radiator with commercially avail-
able fittings upstream on the valve mount-
ings.
separating
®
value (see manu-
V
5