EN – Installation instructions
The radiator may only be installed by a specialist.
Safety instructions
Read these instructions thoroughly prior to
installation/commissioning.
After installation, pass the instructions on
to the end user.
WARNING
Risk of injury!
Take the weight of the radiator into account
(see manufacturer's data).
At 25 kg and above work with lifting equip-
ment or several persons.
Conditions of use
Observe operating conditions for water heat-
ing installations according to local regulations.
Maintain water quality according to local
regulations.
Observe usage limits in humid spaces
according to local regulations.
Use radiator only in closed heating systems.
Store and transport radiator only in the protec-
tive packaging.
Observe minimum clearances between radiator
and surrounding objects for air circulation.
Complaint
Please contact the supplier.
Disposal
Packaging and any parts that are not needed
should be recycled or disposed of properly. Ob-
serve local regulations.
Technical features
•
Operating pressure: max. 10 bar
•
Test pressure: 1.3 x operating pressure
•
Flow temperature: hot water up to 110°C
(230°F)
Directions for installation
Protect radiator from damage
When installing, only remove protective pa-
ckaging at the fastening and connection
points.
Only remove protective packaging completely
during final cleaning or prior to commissioning.
Fixing
Note the number and position of mounting
points (see Fig. A).
Install mounting material according to separa-
te installation instructions.
Note: The two securing screws at the lower
brackets are not required for the short wall brack-
et (two-row installation).
Connection
Unscrew painted blind plugs at the designated
connection points.
Connect radiator with commercially available
fittings upstream.
For connection of the radiator with an inflow and
return at the bottom:
Tightly cap open connections with vent plugs
(top) and blind plugs.
For connection of the radiator with an inflow and
return at the top:
Tightly cap open connections with blind plugs.
Ensure that the radiator is vented via the pi-
ping system,.
WARNING
Permissible type of installation when connec-
ting the radiator with flow and return at the
top with a short wall bracket, the half is in two
rows.
Removed blind plugs may only be used on Kermi
steel panel radiators.
Commissioning
Fill and vent the radiator. Risk of scalding!
Check radiator and connections for leaks.
5