EN – Installation instructions
The radiator may only be installed by a special-
ized tradesman.
Safety instructions
Read these instructions thoroughly prior to
installation/commissioning.
After installation pass the instructions on
to the end used.
DANGER
Life-threatening situation!
Check the condition of the supply lines
(electricity, gas, water).
Do not drill into any lines.
WARNING
Risk of injury!
Take the weight of the radiator into
account (see manufacturer's data).
At 25 kg and above, work with lifting
equipment or several persons.
Operating conditions
Observe operating conditions for wa-
ter heating installations according to
DIN 18380 "VOB German Construction Con-
tract Procedures".
Observe water's condition according to VDI
[Association of German Engineers] 2035
"Prevention of damage in water heating
installations".
Observe limitations of use in damp loca-
tions according to DIN 55900 "Coatings for
radiators".
Use radiator only in closed heating systems.
Store and transport radiator only in the
protective packaging.
Observe minimum clearances between ra-
diator and circumjacent objects for air cir-
culation.
Complaint
Contact the supplier.
Disposal
Packaging and any parts that are not need-
ed should be recycled or disposed of prop-
erly. Observe local regulations.
Technical features
Operating pressure: max. 10 bar
Test pressure: 1.3 x operating pressure
Flow temperature: hot water up to 110 °C
(230 °F)
Directions for installation
Protecting radiator from damage
When installing, only remove protective
packaging at the fastening and connection
points.
Only remove protective packaging com-
pletely during final cleaning or prior to
commissioning.
Fixing
Note the number and position of fastening
points (see Fig. A).
Install fastening material for single-row in-
stallation according to separate installation
instructions.
Connection
Unscrew painted blind plugs at the desig-
nated connection points.
Connect radiator with commercially avail-
able fittings upstream.
For connection of the radiator with an inflow
and return at the bottom:
Tightly cap open connections with vent
plugs (top) and blind plugs.
For connection of the radiator with an inflow
and return at the top:
Tightly cap open connections with blind
plugs.
Ensure that the radiator is vented via the
piping system.
Commissioning
CAUTION
Risk of burns due to squirting hot water
when evacuating air!
Protect your face and hands.
Fill and vent the radiator.
Check radiator and connections for leaks.