3. Operation (For Wired Remote controller)
<Ventilation setting>
Fri
Low
Vent.
ON
RETURN SELECT
MENU
OFF
HOLD
<Returning to the Operation menu>
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Main menu: RETURN
Cursor
ON
RETURN SELECT
MENU
OFF
HOLD
Notes:
During swing operation, the directional indication on the screen
●
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
●
In the following cases, the actual air direction will differ from the
●
direction indicated on the remote controller display.
1. While the display is in "STAND BY" or "DEFROST" states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the tem-
perature setting.
Press the [F3] button to go through
the ventilation setting options in the
order of "Off", "Low", and "High".
* Settable only when Lossnay unit is
connected.
Off
Low
High
Off
Low
• The fan on some models of indoor
units may be interlocked with certain
models of ventilation units.
Press the [RETURN] button to go
back to the Operation menu.
< How to set the fixed up/down air direction (Only for
wired remote controller) >
Note:
This function cannot be set depending on the outdoor unit to be
●
connected.
• For PLFY-NEMU series, only the particular outlet can be fixed to
High
certain direction with the procedures below. Once fixed, only the set
outlet is fixed every time air conditioner is turned on. (Other outlets
follow UP/DOWN air direction setting of remote controller.)
■
Explanation of word
• "Refrigerant address No." and "Unit No." are the numbers given to
each air conditioner.
• "Outlet No." is the number given to each outlet of air conditioner.
(Refer to the illustration below.)
• "Up/Down air direction" is the direction (angle) to fix.
Reset
1
horizontal
Horizontal airflow
Remote controller setting
The airflow direction of this outlet
is controlled by the airflow direc-
tion setting of remote controller.
Outlet No. 2
Outlet No. 1
Note: "0" indicates all outlets.
2
3
4
5
Downward
Fixed
The airflow direction of this outlet is fixed
in particular direction.
* When it is cold because of direct air-
flow, the airflow direction can be fixed
horizontally to avoid direct airflow.
Outlet No. 3
MITSUBISHI
ELECTRIC
label
Outlet No. 4
en
8