Important Safety Instructions - Pentair MYERS Serie Manual Del Usuario

Bombas sumergibles de plástico para sumidero
Ocultar thumbs Ver también para MYERS Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Safety
Im portant Safety
Instructions
SAVE THESE INSTRUCTIONS - This manual contains
important instructions that should be followed during
installation, operation, and maintenance of the product.
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for
one of the following signal words and be alert to the
potential for personal injury!
indicates a hazard which, if not avoided,
will result in death or serious injury.
indicates a hazard which, if not avoided,
could result in death or serious injury.
indicates a hazard which, if not avoided,
could result in minor or moderate injury.
NOTICE addresses practices not related to
personal injury.
Carefully read and follow all safety instructions in this
manual and on pump.
Keep safety labels in good condition. Replace missing
or damaged safety labels.
California Proposition 65 Warning
This product contains chemicals known to
the State of California to cause cancer or birth defects
or other reproductive harm.
1. Know the pump application, limitations, and potential
hazards.
2. Do not use in water with fish present. If any oil leaks
out of the motor it can kill fish.
3. Disconnect power before servicing.
4. Release all pressure within system before servicing
any component.
5. Drain all water from system before servicing.
6. Secure discharge line before starting pump. An
unsecured discharge line will whip, possibly causing
personal injury and/or property damage.
7. Check hoses for weak or worn condition before each
use, making certain that all connections are secure.
8. Periodically inspect sump, pump and system
components. Keep free of debris and foreign objects.
Perform routine maintenance as required.
9. Provide means of pressure relief for pumps whose
discharge line can be shut-off or obstructed.
Performance
GPM (LPM) at total feet (m) of lift
Capacity Gallons(L)/Minute
5
Series
HP
(1.5m)
MS33PT
53
1/3
(201)
MS33PV
MS50PT
63
1/2
(238)
MS50PV
No flow
at height
10
15
20
shown
(3m)
(4.6m)
(6.1m)
below
45
36
24
(170)
(136)
(91)
(7.3m)
54
42
27
(204)
(159)
(102)
(7.3m)
10. Personal Safety:
a. Wear safety glasses at all times when working with
pumps.
b. Keep work area clean, uncluttered and properly
lighted – replace all unused tools and equipment.
c. Keep visitors at a safe distance from work area.
d. Make workshop child-proof – with padlocks, master
switches, and by removing starter keys.
11. When wiring an electrically driven pump, follow all
electrical and safety codes that apply.
12. This equipment is only for use on 115 volt
(single phase) and is equipped with an approved
3-conductor cord and 3-prong, grounding-type plug.
kill. This pump has not been investigated for use in
swimming pool areas. Pump is supplied with a grounding
conductor and grounding-type attachment plug. Be sure it
is connected only to a properly grounded grounding-type
receptacle.
Where a 2-prong wall receptacle is encountered, it must
be replaced with properly grounded 3-prong receptacle
installed in accordance with codes and ordinances that
apply.
13. All wiring should be performed by a qualified
electrician.
14. Make certain power source conforms to requirements
of your equipment.
15. Protect electrical cord from sharp objects, hot
surfaces, oil, and chemicals. Avoid kinking cord.
Replace or repair damaged or worn cords
immediately.
16. Do not touch an operating motor. Modern motors can
operate at high temperatures.
17. Do not handle pump or pump motor with wet hands
or when standing on wet or damp surface, or in water.
kill. If your basement has water or moisture on floor, do
not walk on wet area until all power has been turned off.
If shut-off box is in basement, call electric company or
hydro authority to shut-off service to house, or call your
local fire department for instructions. Remove pump and
repair or re place. Failure to follow this warning can result
in fatal electrical shock.
Do not lift pump by power cord.
Electrical & Switch Specifications
Series
HP
MS33PT
1/3
MS33PV 1/3
24 Ft
MS50PT
1/2
MS50PV 1/2
24 Ft
Risk of electric shock. Can shock, burn or
Risk of electric shock. Can shock, burn or
Motor
Switch Setting in inches
Full
Branch
Load
Circuit Req.
Amps
(Amps)
3.9
14 (35.6)
3.9
7.5 (19.1)
15
4.1
14 (35.6)
4.1
7.5 (19.1)
2
(cm)
On
Off
5 (12.7)
3 (7.6)
5 (12.7)
3 (7.6)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Myers ms33ptMyers ms50ptMyers ms33pvMyers ms50pv

Tabla de contenido