2. Recommendations
Please respect the following values in the order to
ensure the proper operation of this electrolyzer:
Recommended
Salt
concentration
Minimum
Recommended
pH
less than
Recommended
TAC
between
Between
Stabilizer
Recommended
Water
Do not operate when water is
temperature
colder than15°C.
Chlorine
Between 0,5 and 2,5 ppm
concentration
230 volts-50/60 Hz, P. maxi
Connection
100W and must be controlled
by the filter pump.

3. Installation of the unit

Fixing and electrical connections
Before connecting and electrical energization,
the unit must fix to a wall of plant room via the
attachment holes in each corner, using the
supplied screws and plugs. Make sure it is
protected from the weather, avoid direct exposure
to sunlight.
The electrical connection must be performed by a
qualified electrician and comply with NF C 15-100
(2002 edition).
• The powder supply to the unit:
The system must work at the same time as
the filtration pump.
The connection is then made to the filtration
pump's contactor via a 4A fuse box.
A chlorinator that is directly connected to a
230 VAC power supply could damage the
components of the hydraulic circuit and will
not be covered by the warranty.
(Recall, to set the time of filtration, the commonly
used formula is equal to the water temperature ÷
2.
Example: For 28 ° C water filtration time will be 14
hours).
Power of salt electrode: connect the cable for this
purpose. Correctly tighten the nuts. A badly
tightened connection will result overheating.
Precautions to be taken before the intervention
on the unit:
Isolate the electrical system using a separation
device such as energy
• Circuit breaker or disconnect switch.
4,0 g/l
3,2 g/l
Device to be installed for protection against short
circuits or overcurrent
7,6
• Type differential switch 30 mA (power to adopt
10 et 15 ° F
20 à 80 g/m3
40 g/m3
The caliber of the protection device may not
exceed 4 A.
101452 Installation and user manual
following the installation).
12