Ventilator Performance Calculation; Checking The Wall - Bosch HCP34E51UC Instrucciones De Instalación

Ocultar thumbs Ver también para HCP34E51UC:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Round pipes
An inner diameter of 0 8" (200 mm) is recommended.
Flat ducts
The inner cross-section must correspond to the diameter
of the round pipes.
Ø 8" (200 mm) approx. 50.3 inches
Flat ducts should have no sharp deflections.
Use sealing strip for deviating pipe diameters.

Ventilator Performance Calculation

2
2
(324 cm
)

Checking the wall

The wall must be level, vertical and adequately load-
bearing.
The depth of the bore holes must be the same length
as the screws. The wall plugs must have a secure grip.
The enclosed screws and wall plugs are suitable for
solid brickwork. Suitable fasteners must be used for
other structures.
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hcp30e51ucHcp36e51ucHcp34e51uc/01

Tabla de contenido