Connect Electrical Supply
, WARNING
RISK OF ELECTRIC SHOCK
Before wiring the appliance, interrupt the main
electrical circuit at the electrical control cabinet. A
circuit with 120 VAC, 15 or 20 Ampere is required.
Grounding notes: this appliance is equipped with a
distributor box with 3 cables. Use the green-yellow
cable for grounding the appliance. Connect the green-
yellow cable to the grounding cable on the house
connection to prevent electric sthock. Do not under
any circumstances damage or remove the green-
yellow cable. Non-adherence can cause deadly
injuries or electric shock.
1. Remove the left cable passage and the cover of the
motor controller. Fasten the connecting piece for the
installation pipe (listed in cULUS) to the cable passage.
A
Cable passage
B
Cover of the motor controller
2. Connect 1/2" (12.7 mm) installation pipe to motor
controller.
A
Installation pipe
B
Power connection
C
Cable connector listed in UL
14
Attaching flue duct
Hidden surfaces may have sharp edges. Use caution when
reaching behind or under appliance.
1. Remove the protective foil from both flue ducts.
2. Push one flue duct into the other.
Notes
To prevent scratches, lay paper over the edges of
the lower flue duct to protect the surface.
For ducted operation, turn the upper flue duct so
that the ventilation slots point downward.
3. Remove the protective foil from the extractor hood.
4. Place flue ducts on the appliance.
5. Push the inner flue duct upwards and attach it to the
angle brackets on the left and right.