6. When using the cylinder holder:
a. Mount the cylinder holder adapter to the desired side of the
cylinder holder with the provided screws.
b. Attach one end of the 3" piece of provided tubing to the
cylinder holder gas fitting and the other to the gas fitting on the
QuickCheck Station. Ensure that the tubing is fully seated over
the barbs to prevent gas from leaking.
c. Connect the QuickCheck Station to the remaining side of the
cylinder holder with the provided screws.
NOTE: Before operation, be sure to cover unused gas fittings
located on each side of the QuickCheck Station and
cylinder holder with the supplied fitting cover.
ct vibrating alarm functionality.
Figure 1-2. Altair 4 QuickCheck Station Setup
1-4