Options After The Battery Test Results; Time-To-Charge; Test Code (Available In Bmp Version) - Midtronics MicroXL Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GB
* When testing at Jump-Start Post, the analyzer may need to verify the
result. The analyzer will prompt you to retest at the battery posts.
* When testing at Side-Posts, the analyzer may detect corrosion be-
tween the terminals and the side posts. The analyzer will prompt you to
check for corrosion and retest with adapters.
Next, the analyzer will display for 3 seconds the percentage of state of
health as a bar graph.
The analyzer will then display for 3 seconds the percentage of state of
charge as a bar graph.

OPTIONS AFTER THE BATTERY TEST RESULTS

After the battery test results, press the INFO button for the option of
calculating the charge time required to fully charge the battery (available
only for batteries that produce a GOOD-RECHARGE or CHARGE &
RETEST result) or to retrieve a test code (if available). The INFO button
remains active during the results for the battery, starting and charging
systems tests.
Use the UP/DOWN ARROW buttons in the ADDITIONAL INFO screen
to select TIME-TO-CHARGE or TEST CODE and press ENTER.

Time-to-Charge

1. Charge Rate (Amps): Use the ARROW buttons to select the charge
rate and press ENTER.
2. When the analyzer completes the calculation, it will display CHARGE
BATTERY with the time to charge in minutes at your selected
amperage rates.
3. Press ENTER to return to the battery test results.

Test Code (available in BMP version)

1. Select TEST CODE in the ADDITIONAL INFO screen; the analyzer
will display an encrypted 10-digit code.
2. Press ENTER to return to the test results or MENU for the menu
options screen.
E
NGLISH
8

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Micro400xlMicro500xl

Tabla de contenido