Putting on the unit
Adjust shoulder strap around
neck.
Pull both ends of shoulder strap
to the end.
Quickly perform the following
donning steps within approx.
20 seconds.
Activating the starter
Li
ft the hood and the starter will
be activated.
The breathing bag will be filled
within 1 to 2 minutes. If the
starter does not activate,
please breathe out deeply 4 to
5 times into the half mask to
fill the breathing bag and start
chemical reaction of KO
(see
2
"Oxygen Generation" on
page 13). Please expand the
ruff of the hood and breathe
directly into the half mask
Putting on the hood
Expand the ruff of the hood.
Please put in the chin first – put
the hood over the head.
Wearer of glasses leave on their
glasses.
Put long hair under the hood.
Positioning the half mask
Place the inner mask over nose
and mouth.
Pull the head straps to the back. If
not possible, hold the half mask to
the mouth with the hand.
The half mask should fit tightly
around the mouth and nose. The
neck cuff should create a seal
around the neck.
Do not twist or bend breathing
hose.
WARNING!
The half mask needs to be tight against the face! Full beards
could lead to leakage!
If there is noticeable leakage, the straps need to be tightened.
Otherwise misguided air will be not cleaned – risk of
suffocation!
Positioning the oxygen self-rescuer
Wrap the chest strap around and fasten.
Tighten chest strap.
Note
Dräger suggest to practice this procedure with the training
unit.
12
.

Important Rules for Escaping

— Begin your escape calmly; do not rush.
— Plan your escape so that you use the shortest route to safety.
— Behave calmly. Hurrying makes you breathe more quickly and
uses up more oxygen.
— Make sure that the half mask is tight (position of half mask).
— If the air from the oxygen self-rescuer is warm and dry, this is a
sign that the oxygen self-rescuer is functioning correctly.
Any off-taste is quite normal and not dangerous.
— Take care not to damage or squash the breathing bag and so
waste life-saving oxygen.
— If you have to vomit, take the mouthpiece out of your mouth but
keep it sealed with the thumb. Do not vomit into the oxygen self-
rescuer.
Do not start to breathe in again until you have put the mouth-
piece back into your mouth so that you do not inhale toxic
substances from the ambient air.

End of Use

— When breathing becomes more difficult and the breathing bag
begins to deflate, the oxygen supply is coming to an end.
— Any oxygen self-rescuer used underground must be brought to
the surface.
— The hood has an anti-suffocation valve to prevent suffocation.
After escape: Unfasten head straps of half mask and remove
hood.

Disposal

The oxygen self-rescuer is to be discarded after use.
Deactivating used oxygen self-rescuer
— Prevent combustible substances (petrol, grease, solvents etc.)
from entering the oxygen self-rescuer to prevent danger of fire!
— Use protective goggles and gloves.
— Remove starter from the case and discard it according to local
regulations.
— Remove KO
cartridge from the case.
2
— Immerse dismantled KO
cartridge completely in water, until gas
2
bubbles no longer emerge. Neutralize the resulting solution with a
3 % acid e.g. HCl in a 1:1 ratio.
— All plastic components are identified and can be collected accor-
ding to their material characteristics for recycling.
We dispose for you! (price on request)
Please send damaged, opened
rescuers in an approved packaging (e.g. Dräger Transport packaging
63 04 511) to the following address:
Dräger Safety AG & Co. KGaA
Service/Produktrücknahme
Revalstraße 1
23560 Lübeck
Deutschland
Tel.: +49 451 882-0
E-Mail: recycling@draeger.com
1) Before you send the oxygen self-rescuer, please activate the starter!
Afterwards please seal the oxygen self-rescuer in a PE bag.