2 Product description
MENU → SETTINGS → Installer level → Installation configuration
→ Control:
→ Heat generator 1
→ Status:
→ Current flow temperature: °C
→ Circuit 1
→ Status:
→ Target flow temperature: °C
→ OT switch-off
threshold: °C
→ Heat curve:
→ Min. target flow tem-
perature:°C
→ Max. target flow tem-
perature:°C
→ Set-back mode:
The behaviour can be adjusted separately for each heating circuit.
→ Room temp. mod.:
10
Weath.-
It is controlled via the outdoor temperature as soon
comp.
as an outdoor temperature sensor is connected.
Enter the upper limit for the outdoor temperature. If the outdoor
temperature rises above the set value, the system control deac-
tivates heating mode.
The heat curve (→ section "Product description") is the depend-
ence of the flow temperature on the outdoor temperature for the
desired temperature (target room temperature).
Enter the lower limit for the target flow temperature. The system
control compares the set value with the calculated target flow
temperature, and regulates to the larger of these values.
Enter the upper limit for the target flow temperature. The system
control compares the set value with the calculated target flow
temperature, and regulates to the smaller of these values.
→ Eco
The heating function is switched off and the frost
protection function is activated.
At outdoor temperatures that are below 4 °C for
longer than four hours, the system control switches
the heat generator on and regulates to the Set-
back temperature: °C. At an outdoor temperature
above 4 °C, the system control switches the heat
generator off. The monitoring of the outdoor tem-
perature remains active.
Heating circuit behaviour outside of the time peri-
ods. Prerequisite:
– Time-contr. is activated in the Heating →
Mode: function.
– Active or Inactive is activated in the Room
temp. mod.: function.
If Expanded is activated in the Room temp.
mod.:, the system control regulates to the target
room temperature 5 °C independently of the
outdoor temperature.
→ Normal
The heating function is switched on. The system
control regulates to the Set-back temperature: °C.
Prerequisite: Time-contr. is activated in the Heat-
ing → Mode: function.
→ Inactive
Operating and installation instructions sensoHOME 0020288192_00