Technical Data; Power Requirements - Truper BOS-1SP Instrucciones De Instalación Y Funcionamiento

Bomba sumergible
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Data

Voltage and Frequency
Maximum Height / Maximum
Value of Total Gauged Height
Allows Particles Up To
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
The equipment shall be grounded while in use to prevent an electric shock.
• Connect plug into a properly grounded contact or outlet as shown in
example A. Not all contacts or outlets are properly grounded. If not sure,
contact with a certified electrician.
• If the outlet you want to use with the equipment has two poles (2 orifices),
FOR ANY REASON AT ALL DO NOT REMOVE OR ALTER THE PLUG'S EARTH
TERMINAL. Use a temporary adapter as shown in example B and always
connect the earth conductor's lug as indicated.
CAUTION
When using an extension cable, verify the gauge is enough for
the power that your product needs. A lower gauge cable will cause voltage drop
in the line, resulting in power loss and overheating. The following table shows
the right size to use depending on cable's length and the ampere capability
shown in the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
* It is safe to use only if the extensions have a built-in artifact for over current protection. AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
WARNING
When operating power tools outdoors, use a
"For Outdoors Use". These extensions are especially designed for operating outdoors and reduce the risk of
electric shock.
WARNING
All the cabling, power connections and the ground connection of the system shall be in
compliance with the Mexican Official Standard NORMA OFICIAL MEXICANA NOM-001-SEDE,
INSTALACIONES ELÉCTRICAS (UTILIZACIÓN) or with the local codes and municipal by-laws.
Code
Description
Power
Current
Speed
Flow Rate
Maximum Depth
Power Cable
IP Grade
Conductors
Insulating
Power cord grips used in this product: Type "Y".
Thermal insulation on motor winding: Class F
Number of
Conductors
3 (one grounded)
BOS-1SP
12603
Submersible Pump for Dirty Water
120 V
1 Hp
6 A
2850 RPM
57.2 gal/min
16.4'
27.8'
26.2'
1 5/16"
IPX8
18 AWG x 3 C with 221 ºF insulating temperature .
Class I
Build quality: Basic insulation
Authorized Service Center.
CAUTION
Extension Gauge
From 6 ft to 49 ft
|
18 AWG
16 AWG
14 AWG
8 AWG
grounded extension cable labeled
BOS-1-1/2SP
12604
60 Hz
1 1/2 Hp
7 A
61.6 gal/min
29.5'
A
B
Higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3