Technical Data

Outlet and Inlet Diameter
Maximum Suction Depth
Total Manometric Maximum
Height Value / Maximum Height
Maximum Flow
Maximum Water Temperature
WARNING
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
WARNING

Power Requirements

CAUTION
A professional electrician shall carry out the
connection to the power source following the electric diagram to
the right.
CAUTION
Use a separate electric circuit for the pump.
This circuit shall not have a conductor with a gauge lower to #12
and shall be protected with a 20 A time-delay fuse. Before you
connect the motor to the power line. double check the switch is
in the OFF position and the electric current is equal to the one
indicated in the motor nameplate. If the pump is operated with
lower voltage, the motor will get damaged.
WARNING
All wiring, electric connections and the system
ground connection shall comply with the NORMA OFICIAL
MEXICANA NOM-001-SEDE, INSTALACIONES ELÉCTRICAS
(UTILIZACIÓN) or with the local codes and ordinances. Call a certified electrician. It is advisable the pump shall
feed with a circuit that includes a differential circuit breaker with an assigned current to higher than 30 mA
BOAJ-1/2I
Code
Description
Voltage
Frequency
Speed
Current
Power
Conductors
Work Cycle
Insulation
IP Grade
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
Before gaining access to the terminals all power sources should be disconnected.
13555
Stainless Steel Jet Pump
6,5 A
1/2 Hp
130 ft
12 gal/min
18 AWG
50 minutes' work per 20 min rest. Maximum 6 hours' daily
Power Cord Grips used in this product: Type "Y".
Tool Build Quality: Basic insulation
Thermal insulation on motor winding: Class F
127 V~
Motor
Connections
BOAJ-3/4I
13557
127 V
60 Hz
3 400 RPM
7,6 A
3/4 Hp
1 NPT
30 ft
150 ft
16 gal/min
104 °F
16 AWG
Class I
IPX4
Authorized Service Center.
127 V~
Switch
Fuse
Pressure
switch
Motor
Connections
BOAJ-1I
13559
9,5 A
1 Hp
160 ft
17 gal/min
Thermal
connection
3
ENGLISH