Explanation Of Symbols; Technical Data; Putting Into Service - REMS Cobra 22 Instrucciones De Servicio

Ocultar thumbs Ver también para Cobra 22:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
eng

Explanation of symbols

Read the operating instructions before use
Power tool complies with protection class I
Environmentally friendly disposal
CE conformity mark

1. Technical Data

1.1. Article numbers
REMS Cobra 22 drive unit with guide hose
REMS Cobra 32 drive unit with guide hose
Adapter drum Cobra 22/8
Adapter drum Cobra 32/8
Guide gloves, pair
Riveted guide glove, left
Riveted guide glove, right
Guide hose Cobra 22
Guide hose Cobra 32
Drain cleaning cables
Drain cleaning cable 8 × 7.5 m
Drain cleaning cable 16 × 2.3 m
Drain cleaning cable 22 × 4.5 m
Drain cleaning cable 32 × 4.5 m
Drain clean. cable 16 × 2.3 m (6 pcs.) in cable carrier
Drain clean. cable 22 × 4.5 m (5 pcs.) in cable carrier
Drain clean. cable 32 × 4.5 m (5 pcs.) in cable carrier
Drain cleaning cable S 16 × 2 m
Drain cleaning cable S 22 × 4 m
Drain cleaning cable S 32 × 4 m
Drain cleaning cable with core 16 × 2.3 m
Drain cleaning cable with core 22 × 4.5 m
Drain cleaning cable with core 32 × 4.5 m
Cable reduction 22/16
Cable reduction 32/22
Cable carrier 16 (empty)
Cable carrier 22 (empty)
Cable carrier 32 (empty)
Cable joint separator 16
Cable joint separator 22/32
Drain cleaning tools
Straight auger 16
Straight auger 22
Straight auger 32
Bulbous auger 16
Bulbous auger 22
Bulbous auger 32
Funnel auger 16
Funnel auger 22
Funnel auger 32
Retrieving auger 16
Retrieving auger 22
Retrieving auger 32
Serrated blade borer 16/25
Serrated blade borer 22/35
Serrated blade borer 22/45
Serrated blade borer 32/55
Serrated cross-blade borer 16/25
Serrated cross-blade borer 16/35
Serrated cross-blade borer 22/35
Serrated cross-blade borer 22/45
Serrated cross-blade borer 22/65
Serrated cross-blade borer 32/45
Serrated cross-blade borer 32/65
Serrated cross-blade borer 32/90
Serrated cross-blade borer 32/115
Forked cutter 16
Cross-forked cutter 16
Serrated forked cutter 22/65
Serrated forked cutter 32/65
Serrated forked cutter 32/90
Root cutter 22/65
Root cutter 32/65
Root cutter 32/90
Chain flail 16, smooth rings
Chain flail 16, spiked links
Chain flail 22, smooth rings
Chain flail 22, spiked links
Chain flail 32, smooth rings
Chain flail 32, spiked links
1.2. Working range
REMS Cobra 22
Cable Ø 8 mm (max. working length 10 m)
Cable Ø 16 mm (max. working length 40 m)
Cable Ø 22 mm (max. working length 70 m)
REMS Cobra 32
Cable Ø 8 mm (max. working length 10 m)
Cable Ø 16 mm (max. working length 40 m)
Cable Ø 22 mm (max. working length 100 m)
Cable Ø 32 mm (max. working length 70 m)
1.3. Working speed
Working spindle
1.4. Electrical data
Rated voltage
172000
Power input
174000
Rated current
170011
Intermittent service
170012
Protection class
172610
1.5. Dimensions (L × W × H)
172611
Drive unit
172612
044110
044105
1.6. Weights
REMS Cobra 22 drive unit
REMS Cobra 32 drive unit
170200
Tool set 16
171200
Tool set 22
172200
Tool set 32
174200
Cable set 6 × 16 × 2.3 m in cable carrier
171201
Cable set 5 × 22 × 4.5 m in cable carrier
172201
Cable set 4 × 32 × 4.5 m in cable carrier
174201
171205
1.7. Noise information
172205
Emission at workplace
174205
1.8. Vibrations
171210
Weighted effective value
172210
of acceleration
174210
172154
The indicated weighted effective value of acceleration has been measured
174154
against standard test procedures and can be used by way of comparison with
171150
another device. The indicated weighted effective value of acceleration can also
172150
be used as a preliminary evaluation of the exposure.
174150
Attention: The indicated weighted effective value of acceleration can differ
171151
during operation from the indicated value, dependent on the manner in which
172151
the device is used. Dependent upon the actual conditions of use (periodic duty)
it may be necessary to establish safety precautions for the protection of the
171250
operator.
172250

2. Putting into Service

174250
171265
2.1. Electrical connection
172265
174265
WARNING
171270
Ensure that the mains voltage is correct! Before connecting the unit, check
172270
that the mains voltage is the same as specified on the rating p late. Only operate
174270
the machine off the mains using a 30 mA fault current protected switch (FI
171275
breaker).
172275
174275
2.2. Handling and selection of the drain cleaning cable required
171280
The machines REMS Cobra uses lengths of cable which can be connected up
172280
as necessary. The machine REMS Cobra 22 comes either with the tool set 16
172281
or 22 or both. The machine REMS Cobra 32 comes e ither with the tool set 22
174282
or 32 or both. The cables can each be used without any modifications to the
171290
machine.
171291
For the REMS Cobra 32 machine, the cable and tool set 16 can also be used
172290
when using other clamping jaws 16 (accessories). To do this, remove protecting
172291
device (2). Push in the spring brush until it touches using a screw driver. Push
172293
the whole clamping jaw forward and lift out backwards over the spiral pin. Fit
174291
clamping jaw 16 (set), Art.-No. 174101. Then push clamping jaw 16 into the
174293
system bearer, push in the spring brush until it touches and push the clamping
174295
jaw over the spiral pin.
174296
The cables are specially hardened and highly flexible, and can be quickly
171305
extended or shortened by means of T-groove safety connectors.To connect
171306
two lengths, push the T-bar (7) sideways into the T-groove (8). The spring-loaded
172305
thrust pin in the T-bar component locks the two halves together. To separate
174305
them, push back the spring-loaded thrust pin with the releasing tool (9) and
174306
push the T-bar out of the T- g roove. The cables and tools will a lso fit other makes
172310
of drain cleaning machines. An adapter drum for REMS Cobra 22 and REMS
174310
Cobra 32 each with a Ø 8 mm cable, length of 7.5 m, can be supplied as acces-
174311
sory (see 3.4.).
171340
171341
The diameter of the cable required depends on the diameter of the pipe to
172340
be cleaned. For guidance see 1.2.
172341
The type of cable required depends on the length and position of the pipe
174340
concerned and the type of obstruction expected. The standard c able is used
174341
for general drain cleaning operations. Being highly flexible, it is particularly
Pipe Ø 10 – 50 (75) mm
Pipe Ø
20 – 100 mm
Pipe Ø
30 – 150 mm
Pipe Ø 10 – 50 (75) mm
Pipe Ø
20 – 100 mm
Pipe Ø
30 – 150 mm
Pipe Ø
40 – 250 mm
REMS Cobra 22
REMS Cobra 22
740 ¹/min
520 ¹/min
230 V 1~; 50 Hz
230 V 1~; 50 Hz
750 W
1050 W
3.3 A
5.8 A
S3 40% 4/10 min
S3 40% 4/10 min
IP 44 F
IP 44 F
535 × 225 × 535 mm 535 × 225 × 595 mm
21" × 8.9" × 21"
21" × 8.9" × 23.4"
19.1 kg (42.2 lb)
24.6 kg (54.6 lb)
1.8 kg (4.0 lb)
2.3 kg (5.1 lb)
1.9 kg (4.2 lb)
7.4 kg (16.4 lb)
20.6 kg (45.7 lb)
26.3 kg (58.4 lb)
REMS Cobra 22
REMS Cobra 22
75 dB (A)
75 dB (A)
2.5 m/s²
2.5 m/s²