Fault
Liquid flows out of the
pump.
The nozzle does not
spray even though
pressure is present.
Only a spray, emerges,
there is no atomization.
safety valves blows off
too early.
The shut-off valve does
not close.
Liquid emerges without
the lever being activated.
Pressure gage is not
indicating any tank
pressure.
Contact address for additional information → see title page.
Warranty
We guarantee that from the time it is first purchased for a period of the legally valid required
warranty period (maximum 3 years) this device will not exhibit any material or processing
errors. If defects are discovered during the warranty period, MESTO or the distributor in your
country will repair the device without charging for the labor or material or (at the discretion of
MESTO) replace the device itself or its defective parts.
If such defects are discovered, please contact us immediately. We require the invoice or
cash register receipt for purchase of the device.
The warranty does not include wearing parts (seals, O-rings, diaphragm, etc.) or defects
which have occurred due to improper use or unforeseeable circumstances.
CE Declaration of Conformity
Products which belong to the FERROX 3565, 3585 and INOX 3595, 3615 series satisfy the
requirements of the Pressure Equipment Directive 97/23/EC and carry the CE mark.
Cause
Valve disk [26] dirty of
defective.
Filter [25] and / or nozzle [23]
blocked.
Insert [24] is missing
Safety valve [12] is defective.
O-ring [27] on the pressure bolt
not greased.
Defective pressure bolt [28] or
O-ring [27]
Pressure gage [16] defective.
Remedy
Clean or replace the valve disk.
(Fig. 20).
Clean the filter or / and nozzle.
(Fig. 18 +19).
Position the insert in the nozzle.
(Fig. 18).
Replace safety valve. (Fig. 22).
Grease the O-ring of the
pressure bolt. (Fig. 23).
Replace the pressure bolt or
O-ring. (Fig. 23).
Sever attachments (at top, at
bottom, on right) [29]. (Fig. 24)
Open panel [30], unscrew
pressure gage [16] with wrench
and replace. (Fig. 24).
Insert fixing knob [31] (from the
spare parts pouch [3]), push to
the right and insert panel [30].
(Fig. 25).
17